Related Experiment Video
Updated: Aug 10, 2026

A Volumetric Method for Quantification of Cerebral Vasospasm in a Murine Model of Subarachnoid Hemorrhage
Published on: July 28, 2018
Three-dimensional computed tomographic angiography of cerebral aneurysms
D Tampieri1, R Leblanc, J Oleszek
1Department of Neuroradiology, Montreal Neurological Hospital and Institute, McGill University, Quebec, Canada.
Abstract:
We describe our technique and results of dynamic, reconstructed, three-dimensional (3-D) computed tomographic (CT) angiography in our first 18 patients with either complex aneurysms, producing subarachnoid hemorrhage or the compression of neighboring structures, or small asymptomatic aneurysms, and assess the role of this technique in treatment planning. A dynamic, infused CT scan producing 1.5-mm cuts of the area of interest was performed, and the two-dimensional images were reconstructed in three dimensions with the ISG Allegro system (ISG Technologies, Toronto, Ontario, Canada). Results were compared with intra-arterial digital subtraction angiography and magnetic resonance angiography. All aneurysms over 3 mm and half of the aneurysms less than or equal to 3 mm were demonstrated by 3-D CT angiography. The neck of the aneurysm, its relationship to the parent artery and associated branches, and its relationship to surrounding bony structures, such as the anterior clinoid, were also demonstrated. This was especially useful for ophthalmic aneurysms. The 3-D image could be rotated on the screen to mimic the operative approach. The active, filling portion and the thrombosed part of partially thrombosed, giant aneurysms could be seen on the same image, and the active, filling portion could be better appreciated with 3-D CT angiography than with magnetic resonance angiography. A partially treated, acrylic-coated aneurysm that could not be completely assessed otherwise has been demonstrated by this technique. 3-D CT angiography is useful in the evaluation of aneurysms, especially when the local anatomy is obscured or distorted by its mass or by the anterior clinoid.(ABSTRACT TRUNCATED AT 250 WORDS)
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies for Cardiovascular System V: CT
Imaging Studies III: Computed Tomography

