A Protocol to Set Up Needle-Free Connector with Positive Displacement on Central Venous Catheter in Intensive Care Unit
Published on: July 13, 2019
Large-bore central venous catheters for the collection of peripheral blood stem cells
U Hahn1, H Goldschmidt, H Salwender
1Department of Internal Medicine V, University of Heidelberg, Germany.
In order to establish a peripheral blood stem cell graft, repeated apheresis are necessary in the majority of patients. Each apheresis requires withdrawal and reinfusion of blood with high flow rates. To guarantee these flow rates, large-bore catheters are needed for central venous access. Subcutaneously tunneled silicone catheters (Hickman) caused venous thrombosis in 10-40% of the patients. We therefore used polyurethane large-bore catheters only for the time of peripheral blood stem cells (PBSC) collection. Via a Seldinger guidewire following delineation of the right (160 patients) or left (23 patients) internal jugular vein by ultrasound, 183 apheresis catheters have been inserted when the white blood cell count was > 1.0 x 10(9)/L and a measurable population of CD34+ cells was detected by fluorescence-activated cell sorter analysis. The median flow rate was 70 ml/min (range 50-80 ml/min). We observed the following complications: puncture of the carotid artery in 2%, pneumothorax in 0.5%, local infection in 3%, and catheter-related septicemia in only 2% of the patients. At the time of the removal of the catheters, we detected thrombosis of the internal jugular vein in 5% of the patients by ultrasound. The collection of PBSC with short-term, large-bore catheters is effective and is associated with a low incidence of infection and thrombosis.
In order to establish a peripheral blood stem cell graft, repeated apheresis are necessary in the majority of patients. Each apheresis requires withdrawal and reinfusion of blood with high flow rates. To guarantee these flow rates, large-bore catheters are needed for central venous access. Subcutaneously tunneled silicone catheters (Hickman) caused venous thrombosis in 10-40% of the patients. We therefore used polyurethane large-bore catheters only for the time of peripheral blood stem cells (PBSC) collection. Via a Seldinger guidewire following delineation of the right (160 patients) or left (23 patients) internal jugular vein by ultrasound, 183 apheresis catheters have been inserted when the white blood cell count was > 1.0 x 10(9)/L and a measurable population of CD34+ cells was detected by fluorescence-activated cell sorter analysis. The median flow rate was 70 ml/min (range 50-80 ml/min). We observed the following complications: puncture of the carotid artery in 2%, pneumothorax in 0.5%, local infection in 3%, and catheter-related septicemia in only 2% of the patients. At the time of the removal of the catheters, we detected thrombosis of the internal jugular vein in 5% of the patients by ultrasound. The collection of PBSC with short-term, large-bore catheters is effective and is associated with a low incidence of infection and thrombosis.
More Related Videos
07:40Preparation of Peripheral Blood Mononuclear Cell Pellets and Plasma from a Single Blood Draw at Clinical Trial Sites for Biomarker Analysis
Published on: March 20, 2021
06:28Simplified Intrafemoral Injections Using Live Mice Allow for Continuous Bone Marrow Analysis
Published on: November 10, 2023
Related Concept Videos
Stem Cell Therapy for Tissue Regeneration
Types of Stem Cells used in Stem Cell Therapy
The two main cell types that...
Parentral Nutrition: Centeral and Peripheral Parental Nutrition
PN can be administered through two primary routes:
1. Central Parenteral Nutrition (CPN):
CPN involves delivering a high concentration of nutrients through a large vein. This is typically achieved using a Peripherally Inserted Central Catheter (PICC) or,...