Related Experiment Video
Updated: Aug 10, 2026

Safety Precautions and Operating Procedures in an (A)BSL-4 Laboratory: 3. Aerobiology
Published on: October 3, 2016
A positive, individually ventilated caging system: a local barrier system to protect both animals and personnel
G Clough1, J Wallace, M R Gamble
1Alanann Consultancy Services, York, UK.
Abstract:
Most local barrier systems are designed primarily either to protect animals from airborne contamination (exclusion) or to ensure the safety of personnel (hazard containment). Few, other than isolators, are able to cope with the often conflicting demands to do both. The Positive Individually Ventilated system (PIV), which provides pressure adjustable, individual supply and exhaust ventilation to each cage has been tested with this in mind as well as the need to ensure that environmental conditions comply with the requirements of the Home Office Code of Practice (CoP). The results indicate that when compared with traditional open racking the system can reduce both the risk of animals becoming contaminated by airborne infection from the room and the risk of aeroallergens escaping from the cages into the room air. At the same time, environmental conditions within the cages are both less variable and less stressful to the occupants. Conditions of air temperature, relative humidity, ventilation rates, light intensity and (with appropriate air handling) sound levels, all comply with or are better than those required by the CoP. Even with the room air change rate set at only 8/h (8 ac/h) the air distribution system results in draught-free cage ventilation rates of around 50-120 ac/h. This means that with at least the PIV exhaust(s) linked directly into the air conditioning system of the building, the size of the latter and its associated running costs can be reduced by around 50%; this energy saving concept has been approved in principle by the Home Office. Additional benefits include the fact that bedding is kept much drier allowing further cost savings in bedding and associated labour costs. The system is thus beneficial to the animals in protecting them from airborne infection and other stresses. By providing a less variable environment it also helps to minimise the sort of interference with experiments which can arise from that source. Similarly, in accordance with the aims of 'The Control of Substances Hazardous to Health Regulations' (COSHH 1988) and the Health & Safety Executive (HSE 1990), by reducing dust levels in the room air, including allergens, it is also beneficial to the personnel working in the animal rooms.
More Related Videos
05:34Operating and Biocontainment Procedures of a Facility for Laboratory Mice with a Natural Microbiome: Immunophenotyping Procedure
Published on: December 13, 2024
07:45Preparation and Maintenance of Bioexclusion IsoPositive Cage Experiment for Human Fecal Transplantation into Germ-Free Mice
Published on: February 28, 2025
Related Concept Videos
Healthcare Associated Infections II: Preventive Measures
The best practices for preventing healthcare-associated infections include hand hygiene, patient risk...
Transmission-based Precautions II: Airborne and Protective Environment
Airborne precautions:
Use airborne precautions when treating patients known or suspected to have diseases that spread through the air—for example, tuberculosis or measles. These organisms are present in smaller droplets expelled by an infected person and...
Personal Protective Equipment
Standard Precaution
Hand hygiene is the most crucial means to prevent the transmission of disease. Employers are legally required to provide their workers with personal protective equipment (PPE) to minimize exposure or contact with...
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation (NIPPV)
Cardiopulmonary Resuscitation II: ACLS Airway Management