Related Experiment Video
Updated: Oct 2, 2026

Catheterization of the Carotid Artery and Jugular Vein to Perform Hemodynamic Measures, Infusions and Blood Sampling in a Conscious Rat Model
Published on: January 30, 2015
The effect of arterial lines on blood-drawing practices and costs in intensive care units
L L Low1, G R Harrington, D P Stoltzfus
1Department of Medicine, Walter Reed Army Medical Center, Washington, DC, USA.
Study Objective:
To determine whether the presence of an indwelling arterial access line leads to differences in blood-drawing practices and costs, in patients with similar APACHE II scores, in the ICU.
Design:
Prospective, observational.
Setting:
Adult surgical and medical ICUs at a large military tertiary care hospital.
Patients:
Twenty-five adult (ie, above 18 years old) patients with arterial access lines and 25 adult patients without arterial access lines. Each had APACHE II of 9 to 20 and none had any central venous access.
Measurements And Results:
A survey of the arterial line blood-drawing habits of critical care nurses at our hospital revealed a 2.99-mL mean discard blood volume to clear an arterial line, with only 9.4% not discarding any blood. For each patient enrolled in the study, the number of blood tests and blood draws were recorded during the first two 24-h periods after admission to the ICU. The amount of blood required by the laboratory for each blood test was totalled. In the arterial line group, the mean discard volume was added to the total for each blood-drawing procedure. Increases were found in the number of blood tests (29% increase, p = 0.013), blood-drawing procedures (30% increase, p = 0.014), and the amount of blood volume (44% increase, p < 0.001) sent from patients with arterial lines compared to those without.
Conclusion:
When APACHE II scores are similar, the presence of an arterial access line may lead to increased blood drawing from patients in ICUs.
Related Concept Videos
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessment of blood pressure in brachial artery(two-step method)
Pre-Procedural Guidelines for Assessing Blood Pressure
Blood Studies I: ABG and VBG
Arterial Blood Gas (ABG)
Arterial Blood Gas (ABG) studies are crucial for assessing the lungs' ability to supply oxygen and remove carbon dioxide, reflecting the patient's ventilation status. They also help understand the kidneys' capacity to reabsorb or...
Parentral Nutrition: Centeral and Peripheral Parental Nutrition
PN can be administered through two primary routes:
1. Central Parenteral Nutrition (CPN):
CPN involves delivering a high concentration of nutrients through a large vein. This is typically achieved using a Peripherally Inserted Central Catheter (PICC) or,...
Cardiac Catheterization IV: Nursing Management

