Related Experiment Video
Updated: Aug 10, 2026

A Multicenter MRI Protocol for the Evaluation and Quantification of Deep Vein Thrombosis
Published on: June 2, 2015
Clinical safety of gadopentetate dimeglumine
K L Nelson1, L M Gifford, C Lauber-Huber
1Department of Radiology, Omaha, NE 68105, USA.
Purpose:
To quantify the rate of adverse reactions to gadopentetate dimeglumine.
Materials And Methods:
Magnetic resonance (MR) imaging was performed in 15,496 patients in April-September 1992. Data were collected before and after intravenous administration of 0.1 mmol/kg gadopentetate dimeglumine.
Results:
Adverse reactions occurred in 2.4% (n = 372) of patients. Symptoms abated the same or next day in 94.1% (n = 350). Whereas onset occurred within 30 minutes after injection in 49.7% (n = 185), onset occurred more than 1 hour after injection in 44.9% (n = 167). Two serious adverse reactions occurred and were attributed to underlying disease. The rate of adverse reaction was 3.7% in patients with a history of asthma (31 of 831 patients) or allergy (144 of 3,860 patients). Patients with previous reactions to an MR imaging or iodinated contrast agent had an adverse-reaction rate in this study of 21.3% (16 of 75) and 6.3% (54 of 857), respectively. The rate of adverse reaction was 2.2% when gadopentetate dimeglumine was administered slowly and 2.9% when it was administered rapidly.
Conclusion:
Findings confirm the safety of gadopentetate dimeglumine.
Related Concept Videos
Magnetic Resonance Imaging
Radiological Investigation I: X-ray and CT
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies for Cardiovascular System IV: CMRI
Imaging Studies for Cardiovascular System V: CT
Imaging Studies III: Computed Tomography