Related Experiment Videos
Rapid bulk replacement of acceptor membrane by donor membrane during phagosome to phagoacidosome transformation in
1Pacific Biomedical Research Center, University of Hawaii, Honolulu 96822, USA.
Abstract:
The extent to which a donor membrane will be retrieved, or if it is retrieved at all after it fuses with an acceptor membrane, is usually difficult to determine. We have studied the dynamics of membrane retrieval in the phagosome system of Paramecium multimicronucleatum using six monoclonal antibody markers. Our previous freeze-fracture and transmission electron microscopic studies have indicated that extensive changes take place in the membrane of the young phagosome as it progresses through its cycle. Using immunofluorescence and immunoelectron microscopy to determine the times of entry and exit of these individual antigens into the digestive vacuole system, we showed that two hydrophilic antigens, one located on the cytosolic and one on the lumenal side of the discoidal membrane (phagosome membrane precursor), were completely retrieved from the phagosome by tubulation within the first three minutes. At the same time that this membrane was retrieved, membrane from a second population of vesicles, the acidosomes, fused with the phagosome to produce the phagoacidosome. On the basis of immunogold localization on cryosections of a total of six antigens, the two specific for phagosome/discoidal vesicle membrane as well as four specific for the acidosome/phagoacidosome membrane, this replacement is total. We also showed that in the presence of the actin-active drug cytochalasin B, this replacement was essentially prevented. However, when vacuole acidification was neutralized by ammonium chloride, this replacement process continued unaffected after a lag. Consequently, acidification, per se, is not required to trigger the replacement of the phagosome membrane. We conclude, on the basis of these studies as well as our previous freeze-fracture studies that during phagoacidosome formation most of the acceptor membrane is retrieved and is replaced by the donor membrane. This shows that at least one cell type possesses the mechanisms needed to substantially replace the membrane of a phagosomal compartment when radical and rapid changes are needed to modulate the digestive and absorptive processes.
Insights
Membrane dynamics in Paramecium phagosomes show rapid replacement of acceptor membrane by donor membrane during phagoacidosome formation. This process is actin-dependent but not triggered by acidification.
Area of Science:
- Cell Biology
- Membrane Dynamics
- Phagocytosis
Background:
- Membrane retrieval after fusion is poorly understood.
- Phagosome membrane undergoes significant changes during its cycle.
Purpose of the Study:
- Investigate membrane retrieval dynamics in Paramecium phagosomes.
- Determine the extent and mechanism of membrane replacement during phagoacidosome formation.
Main Methods:
- Utilized six monoclonal antibody markers.
- Employed immunofluorescence and immunoelectron microscopy.
- Analyzed antigen entry/exit and immunogold localization on cryosections.
Main Results:
- Hydrophilic antigens were completely retrieved from phagosomes within three minutes via tubulation.
- Donor membrane from acidosomes fully replaced acceptor membrane during phagoacidosome formation.
- Actin disruption prevented replacement, while acidification did not affect the process.
Conclusions:
- Phagosome membrane is substantially replaced by donor membrane during phagoacidosome formation.
- Cellular mechanisms exist for rapid and extensive phagosomal compartment membrane replacement.
- Acidification is not required to trigger this membrane replacement process.