Erroneous mass spectrometer readings caused by desflurane and sevoflurane

M Abel1, J B Eisenkraft

  • 1Department of Anesthesiology, Mount Sinai School of Medicine, City University of New York, NY 10029-6574, USA.

Journal of Clinical Monitoring
|May 1, 1995
PubMed
Abstract

Related Concept Videos

Mass Spectrum01:23

Mass Spectrum

A mass spectrum is the graphical representation of the relative abundance of the charged fragments in an analyte plotted against their mass-to-charge ratio (m/z). The plot's x-axis represents the ratio of the mass of the charged fragment to the number of charges it carries. The y axis of the plot represents the relative abundance of each charged species. The relative abundance is calculated from the signal intensity of each charged species recorded at the detector. The most intense signal (the...
High-Resolution Mass Spectrometry (HRMS)01:15

High-Resolution Mass Spectrometry (HRMS)

The resolution of a mass spectrometer depends on the efficiency of separating ions with different ion masses. The mass of an atom is approximated to the sum of the masses of protons and neutrons inside, considering the masses of protons and neutrons as equal. However, the masses of the proton (1.6726 × 10−24 g) and neutron (1.6749 × 10−24 g) are not truly equal. There is a minor error in the expression of atomic masses relative to the simplest atom of hydrogen. For example, the mass of helium...
Mass Spectrum: Interpretation01:24

Mass Spectrum: Interpretation

An unknown compound can be established by identifying the molecular ion peak in the mass spectrum. The molecular ion peak is often weak or absent due to the predominance of fragmentation in high-energy electron beams. In such cases, a soft-energy electron beam can be used to scan the spectrum to enhance the intensity of the molecular ion peak. Additionally, chemical ionization, field ionization, and desorption ionization spectra are used to obtain a relatively intense molecular ion peak.To...
Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences01:20

Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences

Inductively coupled plasma–mass spectrometry (ICP–MS) is a highly selective and sensitive technique for accurate elemental analysis. Though the analysis of ICP–MS mass spectra is comparatively straightforward, it is affected by spectroscopic and non-spectroscopic interferences. Spectroscopic interferences arise when the plasma contains ionic species with an m/z value the same as the analyte ion. Spectroscopic interference can be categorized as isobaric, polyatomic ions, and refractory oxide ion...
Atomic Absorption Spectroscopy: Interference01:25

Atomic Absorption Spectroscopy: Interference

Interference leads to systematic error in atomic absorption (AA) measurements by enhancing or diminishing the analytical signal or the background. These interferences can be grouped into three main categories: spectral interference, chemical interference, and physical interference.
Spectral interference occurs when signals from other elements or molecules overlap with the analyte signal, falsely elevating or masking the analyte's absorbance. This interference can be corrected using Zeeman,...
Inhalational Anesthetics: Overview01:20

Inhalational Anesthetics: Overview

Inhalation anesthetics are drugs that induce general anesthesia upon inhalation. They work by increasing the sensitivity of GABAA receptors or inhibiting NMDA receptors, leading to a decrease in central nervous system activity. The depth of anesthesia can be rapidly adjusted by changing the concentration of the inhaled gas. Some common examples of inhalational anesthetics include volatile liquids like isoflurane, desflurane, sevoflurane and gases like xenon and nitrous oxide. Isoflurane, a...