The 3-loop technique: a reliable technique for anterior pubic fixation in bladder exstrophy

S J Karmarkar1, J V Patankar, S N Oak

  • 1Department of Pediatric Surgery, Lokmanya Tilak Municipal General Hospital, Bombay, India.

The Journal of Urology
|September 1, 1995
PubMed
Summary

The 3-loop method provides secure anterior pubic fixation for bladder exstrophy closure, leading to successful outcomes. This technique is reliable and improves urological results in pediatric patients.

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Is an Antireflux Procedure Necessary for a Successful Appendicostomy? The Simplified Malone Antegrade Continence Enema Procedure.

Journal of Indian Association of Pediatric Surgeons·2023
Same author

Isolation and Evaluation of Mucilage of Adansonia digitata Linn as a Suspending Agent.

Journal of pharmaceutics·2015
Same author

A novel microdeletion affecting the CETP gene raises HDL-associated cholesterol levels.

Clinical genetics·2015
Same author

Surgical checklist application and its impact on patient safety in pediatric surgery.

Journal of postgraduate medicine·2015
Same author

Needle in a haystack: Intraoperative breakage of pediatric minimal access surgery instruments.

Journal of postgraduate medicine·2014
Same author

Medical simulation: a virtual world at your doorstep.

Journal of postgraduate medicine·2014

Area of Science:

  • Pediatric Urology
  • Surgical Techniques
  • Congenital Anomalies

Background:

  • Successful closure of bladder exstrophy is critical for long-term urological function.
  • Current methods for anterior pubic fixation have limitations.
  • Secure fixation is essential for optimal outcomes in exstrophy repair.

Purpose of the Study:

  • To describe the 3-loop technique for anterior pubic fixation in bladder exstrophy.
  • To evaluate the efficacy and reliability of the 3-loop method.
  • To assess the impact of this technique on urological outcomes.

Main Methods:

  • The 3-loop technique was used for anterior pubic fixation in 7 consecutive bladder exstrophy cases.
  • Patients ranged in age from newborn to 9 years at the time of closure.

Related Experiment Videos

  • The study period spanned 2 years.
  • Main Results:

    • All 7 closures were successful with the 3-loop technique.
    • No instances of wire cutting, bony erosion, or erosion into the bladder neck/urethra were observed.
    • Postoperative traction duration was reduced to 2 weeks.

    Conclusions:

    • The 3-loop method is a useful and reliable technique for anterior pubic fixation in bladder exstrophy.
    • This method contributes positively to the overall urological outcome for patients.
    • Secure pubic fixation is paramount for successful bladder exstrophy repair.