CT appearance of a traumatic cataract

Y Segev1, M Goldstein, M Lazar

  • 1Department of Diagnostic Radiology, Tel-Aviv Sourasky Medical Center, Israel.

AJNR. American Journal of Neuroradiology
|May 1, 1995
PubMed
Summary

Traumatic cataracts can appear on CT scans as a lens that is darker than normal with a brighter rim. This CT imaging finding is due to fluid entering the lens through a tear in its capsule.

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Ophthalmic artery calcification in a patient with renal failure.

Neuroradiology·2002
Same author

[Presurgical neuropsychological assessment in epilepsy: the Wada test].

Harefuah·2000
Same author

"The disappearing lens": failure of CT to image the lens in traumatic intumescent cataract.

Journal of computer assisted tomography·1999
Same author

The use of beta-subunits of gonadotrophin hormones in the follow-up of clinically non-functioning pituitary tumours.

Clinical endocrinology·1998
Same author

Neuroimaging of children with partial seizures.

Seizure·1998
Same author

Primary intramedullary spinal melanoma: diagnostic and treatment problems.

Journal of neuro-oncology·1998

Area of Science:

  • Ophthalmology
  • Radiology
  • Medical Imaging

Background:

  • Traumatic cataract is a significant cause of vision loss.
  • Computed Tomography (CT) is a crucial imaging modality in evaluating ocular trauma.

Observation:

  • A case of traumatic cataract was evaluated using CT.
  • The cataract presented as a hypodense lens with a hyperdense rim on CT imaging.

Findings:

  • The observed CT appearance is directly related to the cataract's pathogenesis.
  • A capsular tear allows fluid to enter the lens, causing the characteristic imaging findings.

Implications:

  • This case highlights the utility of CT in diagnosing traumatic cataracts.
  • Understanding the CT presentation aids in prompt diagnosis and management of traumatic lens injuries.