Protocol for Relative Hydrodynamic Assessment of Tri-leaflet Polymer Valves
Published on: October 17, 2013
Biological valves beyond fifteen years: the Wessex experience
T J Edwards1, S A Livesey, I A Simpson
1Wessex Cardiothoracic Centre, Southampton General Hospital, United Kingdom.
Abstract:
Between 1975 and 1979, 443 biological valves (298 Carpentier-Edwards, 134 homograft, and 11 Hancock valves) were implanted in 415 patients (age, 16 to 77 years; mean, 59 years) with an operative mortality of 2.9%. Total follow-up was 4,248 patient-years. Overall event-free survival was 60% +/- 1.5% (standard deviation) at 10 years and 29% +/- 1.4% at 15 years. Ten-year and 15-year event-free survival were 72% +/- 3.4% and 41% +/- 3.3% for aortic homografts, 62% +/- 3% and 33% +/- 2.8% for isolated aortic xenografts, and 43% +/- 3.5% and 14% +/- 3.0% for isolated mitral xenografts. Freedom from structural valve degeneration was 87% +/- 1.3% and 63% +/- 2.5% for all patients at 10 and 15 years, respectively, 86% +/- 2.7% and 58% +/- 4.1% for aortic homografts, 93% +/- 1.8% and 76% +/- 5.1% for aortic xenografts, and 75% +/- 4.0% and 47% +/- 7.4% for mitral xenografts. Of the 110 remaining patients, echocardiography was performed in 61 patients (23 aortic xenograft, 24 aortic homograft, 9 mitral xenograft, and 5 tricuspid xenograft) between 14 and 17 years after implantation. An early diastolic murmur was heard in 57% of all aortic valve replacements (AVRs) 62.5% of homograft AVRs, and 52% of xenograft AVRs. Echocardiographically, aortic regurgitation was detected in 79%, 83%, and 74% of all AVRs, homografts, and xenografts, respectively. Aortic stenosis was present clinically in 11% of all AVRs, 4% of homograft AVRs, and 17% of xenograft AVRs.(ABSTRACT TRUNCATED AT 250 WORDS)
More Related Videos
07:59A Strain Gauge Monitor (SGM) for Continuous Valve Gape Measurements in Bivalve Molluscs in Response to Laboratory Induced Diel-cycling Hypoxia and pH
Published on: August 1, 2018
05:31Transcatheter Pulmonary Valve Replacement from Autologous Pericardium with a Self-Expandable Nitinol Stent in an Adult Sheep Model
Published on: June 8, 2022
Related Concept Videos
Wheatstone Bridge
Thus, for accurate resistance measurements, a...
Heart Valves
The AV valves prevent the backflow of blood from the ventricles to the atria during ventricular contraction. These valves function with the assistance of the chordae tendineae and papillary muscles. When the ventricles are relaxed, the chordae tendineae are slack, allowing blood to flow from the atria into the...
Electro-mechanical Systems
A key component of the DC motor is the armature, a rotating circuit positioned within a magnetic field. As an electric current passes through the...
Mitral Valve Prolapse I: Introduction
Mitral Stenosis I: Introduction
Single Pipe Systems
In a Type I problem, fluid properties (density and viscosity), pipe characteristics (including diameter, length, and surface roughness), and the flow rate or average velocity are known. The...