Advantages of continuous measurement of cardiac output 24 h a day
J P Montani1, H L Mizelle, B N Van Vliet
1Department of Physiology and Biophysics, University of Mississippi Medical Center, Jackson 39216-4505, USA.
Abstract:
To test the hypothesis that continuous measurement of cardiac output 24 h a day would provide a better day-by-day reproducibility of the daily average cardiac output than acute measurements, we developed a computer-assisted method to monitor cardiac output continuously using an electromagnetic flow transducer. Because the diastolic aortic flow, which is used as a zero-flow reference, can drift significantly with electromagnetic flow probes, automatic tracking of the diastolic flow baseline was considered essential for long-term measurements. To accomplish this, the analog pulsatile flow signal was digitally converted and processed by an IBM PC to correct for signal drift on a beat-per-beat basis. Using this computerized system in 19 chronically instrumented dogs, we compared the values of cardiac output during 5 consecutive control days, measured either for 20 h each day (allowed 4 h for special care) or for 30 min in the morning when the trained dogs were required to lie quietly in their cages. The results show that the coefficient of variation of the five daily averages in cardiac output for each individual dog was three times smaller when cardiac output was measured 20 h each day (2.9 +/- 0.3 vs. 9.7 +/- 1.0%). Whole-day coefficients of variation were also smaller for mean arterial pressure, heart rate, stroke volume, and total peripheral resistance. Because of this greater day-by-day reproducibility, continuous monitoring of cardiac output is likely to be more sensitive to small changes in cardiac output induced by experimental protocols.
Related Concept Videos
Pulse
Pulse Rate and its Significance
Pulse rate, often measured in beats per minute (bpm), reflects the heart rate (HR), which is influenced by numerous factors such as stress, physical activity, and hormonal changes. A normal resting adult pulse rate falls between...
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac muscle...
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Cardiac Output and Stroke Volume
In an average resting adult male, the typical cardiac output averages...
Exercise and Cardiac Output
Sustained exercise increases the muscles' oxygen demand, which can be met...
Holter Monitor: 24-Hour Monitoring


