Limitations of craniocaudal thallium-201 and technetium-99m-sestamibi mammoscintigraphy
A H Maurer1, D F Caroline, F J Jadali
1Department of Diagnostic Imaging, Temple University Hospital, Philadelphia, Pennsylvania 19140, USA.
Unlabelled:
Previous studies with 201Tl and 99mTc-sestamibi (MIBI) have used large field of view (LFOV) cameras not optimized for breast imaging. The purpose of this study was to compare these agents and to determine if a small field of view (SFOV) camera designed to minimize the camera-to-breast distance could improve tumor detection.
Methods:
A 28-cm (SFOV) camera was fitted with slant-hole and diverging collimators to perform craniocaudal scintigraphy for direct comparison with mammography. Of the 46 patients studied, 20 had 201Tl imaging alone and 26 had combined 201Tl and MIBI imaging. LFOV (40 cm) breast and axillary images also were obtained. Visual and quantitative analyses of tumor uptake were performed.
Results:
The SFOV camera with nonparallel collimation showed variable 201Tl and MIBI normal breast activity. This was partly due to significant scatter from cardiac and abdominal activity. Overall, 201Tl had a sensitivity of 53%, which was 67% for tumors > or = 1.5 cm and 20% for tumors < or = 1.5 cm. MIBI sensitivity was 90% (9/10) for lesions > or = 1.5 cm. Specificity was 93% for 201Tl and 83% for MIBI. There was no significant difference in 201Tl (1.76 +/- 0.55) and MIBI (1.82 +/- 0.95) tumor uptake ratios (p = 0.75).
Conclusion:
Technetium-99m-MIBI was more sensitive than 201Tl for imaging lesions > or = 1.5 cm. Craniocaudal positioning minimized the camera-to-breast distance but did not increase 201Tl detection of tumors < 1.5 cm and increased background breast activity due to scatter.
Related Concept Videos
Magnetic Resonance Imaging
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...
Radiological Investigation I: X-ray and CT
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Imaging Studies for Cardiovascular System IV: CMRI