Related Experiment Video
Updated: May 2, 2026

Cardiac Stress Test Induced by Dobutamine and Monitored by Cardiac Catheterization in Mice
Published on: February 10, 2013
Dobutamine stress echocardiography compared with dipyridamole thallium-201 single-photon emission computed tomography
1Department of Internal Medicine, National Taiwan University Hospital, Taipei.
Abstract:
To compare the diagnostic value of dobutamine stress echocardiography with dipyridamole thallium-201 single-photon emission computed tomography (SPECT) in detecting coronary artery disease (CAD), we performed both tests on 54 patients who also underwent coronary arteriography. Dobutamine was infused at an incremental regimen of 5, 10, 20, 30 and 40 micrograms.kg-1.min-1. Dipyridamole was infused at a rate of 0.14 mg.kg-1.min-1 over 4 min. Dobutamine stress echocardiography detected 40 (93%) and SPECT 42 (98%, P = ns) of the 43 patients with significant CAD, defined as > or = 50% diameter stenosis. The specificity was 73% (8 of 11) for both tests. The sensitivity for detecting individual coronary artery stenosis with dobutamine stress echocardiography was 81% (30 of 37) for the left anterior descending artery, 75% (24 of 32) for the right coronary artery, and 61% (17 of 28) for the left circumflex artery. For SPECT it was 89%, 97% (P < 0.05 vs dobutamine stress echocardiography) and 75%, respectively. Among the 97 stenotic coronary arteries, 17 had mild to moderate stenosis (50%-69% diameter stenosis) and 80 had severe stenosis (> or = 70% diameter stenosis). With dobutamine stress echocardiography, 53% of the arteries with mild to moderate stenosis were identified vs 78% of those with severe stenosis (P < 0.05). With SPECT, the sensitivity was 82% (14 of 17) in mild to moderate stenosis and 89% (71 of 80) in severe stenosis (P = ns). No major side effects occurred during either test. Thus, both dobutamine stress and SPECT are highly sensitive for detection and localization of CAD.(ABSTRACT TRUNCATED AT 250 WORDS)
More Related Videos
06:39Ultrasound Based Assessment of Coronary Artery Flow and Coronary Flow Reserve Using the Pressure Overload Model in Mice
Published on: April 13, 2015
09:05Transthoracic Speckle Tracking Echocardiography for the Quantitative Assessment of Left Ventricular Myocardial Deformation
Published on: October 20, 2016
Related Concept Videos
Exercise Stress Test
Exercise stress testing, commonly known as a treadmill test, is a noninvasive procedure used to evaluate cardiovascular function and diagnose heart conditions.
Definition
An exercise stress test measures the heart's response to exertion using a treadmill or stationary bicycle. Chest electrodes record the heart's electrical activity through an ECG, and blood pressure is monitored regularly.
Purposes
Imaging Studies for Cardiovascular System I:Echocardiography
Indications: Echocardiography is utilized to diagnose heart failure, valve disorders, and myocardial infarction. It also assesses cardiac structures' size, shape, and motion,...
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for...
Imaging Studies for Cardiovascular System V: CT
Acute Coronary Syndrome III: Diagnostic Studies
Dysrhythmias V: Evaluating Dysrhythmias