Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Experiment Videos

[A new 3-dimensional head fixation device for brain imaging]

R Goto1, R Kawashima, S Yoshioka

  • 1Institute of Development, Aging and Cancer, Tohoku University.

Kaku Igaku. the Japanese Journal of Nuclear Medicine
|July 1, 1995
PubMed
Summary

Researchers created a new tool to keep a person's head perfectly still during brain scans. This device uses a custom-molded mask and a special pillow to ensure the head stays in the exact same spot, even when switching between different types of imaging machines. By stabilizing the head, this system helps doctors and scientists get clearer, more accurate pictures of brain activity.

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

[Continuous epidural infusion of bupivacaine and buprenorphine for postoperative pain relief].

Masui. The Japanese journal of anesthesiology·1992
Same author

[Sevoflurane anesthesia for asthmatic patients: report of five cases].

Masui. The Japanese journal of anesthesiology·1992
Same author

Occurrence of the nfxB type mutation in clinical isolates of Pseudomonas aeruginosa.

Antimicrobial agents and chemotherapy·1992
Same author

Identification of the binding site of 55kDa tumor necrosis factor receptor by synthetic peptides.

Biochemical and biophysical research communications·1992
Same author

Two reactions are simultaneously catalyzed by a single enzyme: the arginine-dependent simultaneous formation of two products, ethylene and succinate, from 2-oxoglutarate by an enzyme from Pseudomonas syringae.

Biochemical and biophysical research communications·1992
Same author

Molecular cloning in Escherichia coli, expression, and nucleotide sequence of the gene for the ethylene-forming enzyme of Pseudomonas syringae pv. phaseolicola PK2.

Biochemical and biophysical research communications·1992

Area of Science:

  • Neuroimaging instrumentation within brain mapping research
  • Medical device engineering for head fixation studies

Background:

No prior work had resolved the challenge of maintaining consistent head positioning across multiple imaging modalities. Standard stabilization methods often fail to provide the precision required for longitudinal brain function analysis. This uncertainty drove the development of specialized hardware to minimize movement artifacts. Prior research has shown that even minor shifts during scanning sessions can compromise data quality. Existing solutions frequently lack the versatility needed for both magnetic resonance imaging and positron emission tomography. That gap motivated the creation of a unified fixation framework for clinical research. Scientists require reliable tools to ensure that anatomical and functional data align perfectly. This report introduces a novel apparatus designed to address these persistent limitations in neuroimaging protocols.

Purpose Of The Study:

The aim of this study is to introduce a new apparatus for stabilizing the head during functional brain scanning. Researchers sought to address the difficulty of keeping subjects perfectly still during long procedures. The project specifically targets the need for precise positional alignment across multiple imaging modalities. This motivation stems from the requirement to accurately overlay data from magnetic resonance imaging and positron emission tomography. The team intended to create a system that is both reliable and practical for routine clinical use. They aimed to overcome the limitations of existing immobilization tools that often fail to provide sufficient consistency. By developing this device, the authors hope to improve the quality of functional activation studies. This work provides a clear solution for researchers struggling with movement artifacts in their imaging data.

Keywords:
neuroimaging hardwarepositional reproducibilitythermoplastic maskclinical scanning

Frequently Asked Questions

The system utilizes a thermoplastic resin mask combined with a styrene foam bead pillow. This combination secures the skull, while an integrated bite bridge prevents rotational movement during the scanning process.

The apparatus incorporates a thermoplastic resin face mask originally designed for radiotherapy. This material allows for a custom fit that conforms to individual facial features, ensuring the head remains in a fixed position.

A bite bridge is necessary to provide a stable reference point for the subject. This feature prevents subtle shifting that might otherwise occur during long imaging sessions, ensuring the head remains perfectly aligned.

The plastic frame acts as the primary structure, supporting the foam pillow and the resin mask. It provides the rigid foundation required to hold the various components together during the scanning procedure.

Related Experiment Videos

Main Methods:

The review approach examines the construction of a novel stabilization apparatus for neuroimaging. Investigators utilized a plastic frame as the primary structural support for the entire assembly. A pillow containing styrene foam beads provides the necessary cushioning for the subject. The team adapted a thermoplastic resin mask, typically used in radiotherapy, to create a custom facial mold. They incorporated a bite bridge into the mask to enhance overall stability. The design process focused on achieving high reproducibility across magnetic resonance imaging and positron emission tomography. Researchers evaluated the system by testing its ability to immobilize subjects during simulated scanning sessions. This approach highlights the integration of existing medical materials into a specialized neuroimaging tool.

Main Results:

Key findings from the literature demonstrate that the apparatus successfully immobilizes the head during scanning. The system achieves high positional reproducibility, which is essential for comparing different imaging modalities. The authors report that the device remains stable during both magnetic resonance imaging and positron emission tomography sessions. Their data suggest that the custom-molded mask provides a secure fit for various subjects. The integration of the bite bridge significantly reduces unwanted movement compared to standard stabilization techniques. These results confirm that the system is suitable for practical use in clinical environments. The researchers observed that the device effectively supports activation studies by maintaining consistent head orientation. This stability ensures that functional data remains accurate throughout the entire imaging process.

Conclusions:

The authors propose that their apparatus effectively stabilizes the skull during complex scanning procedures. This system achieves high levels of positional consistency across distinct diagnostic platforms. Synthesis and implications suggest that researchers can now perform activation studies with greater confidence in their spatial alignment. The findings indicate that the integration of thermoplastic materials provides a robust solution for patient immobilization. This approach facilitates the comparison of functional data derived from different imaging technologies. The team asserts that their design meets the practical requirements for routine clinical application. Future investigations might utilize this hardware to improve the accuracy of brain mapping experiments. Overall, the device serves as a reliable tool for maintaining head orientation throughout the entire imaging workflow.

The researchers measured the reproducibility of the head position across different sessions. They observed that the system maintains consistent alignment, which is critical for accurate data comparison between magnetic resonance imaging and positron emission tomography.

The authors claim that this system is particularly useful for positron emission tomography activation studies. They suggest that the device improves the reliability of functional brain mapping by reducing movement-related errors.