Delayed effects of radiofrequency energy on accessory atrioventricular connections
J J Langberg1, S M Borganelli, S J Kalbfleisch
1University of Michigan Hospitals, Ann Arbor 48109-0022.
Abstract:
The purpose of this study was to determine the incidence and characteristics of delayed effects on conduction through accessory atrioventricular (AV) connections after apparently successful attempts at radiofrequency catheter ablation. Among 450 patients who had 471 accessory AV connections, the ablation procedure was unsuccessful in 26 patients (6%), as defined by persistent conduction through the accessory AV connection 60 minutes after the final application of radiofrequency energy. In 6/26 unsuccessfully treated patient (24%), conduction through the accessory AV connection disappeared on a delayed basis. At least once during the ablation procedure, conduction through each of these 6 accessory AV connections was transiently eliminated for 10 seconds to 60 minutes. Five of these accessory AV connections were left-sided and one was posteroseptal; one was concealed and five were manifest. Conduction through the accessory AV connection disappeared on a delayed basis 6-18 hours after the ablation procedure in 4 patients, and at some time between 1-5 days or 1-60 days in the other 2 patients. In 2 patients, the delayed effect was only transient, while in 4 patients, conduction through the accessory AV connections did not return during 5-23 months of follow-up. In conclusion, up to 15% of patients who undergo an apparently unsuccessful attempt at radiofrequency ablation of an accessory AV connection may later manifest a permanent loss of conduction through the accessory AV connection.
Related Concept Videos
Electrophysiology of Normal Cardiac Rhythm
Mechanism of Cardiac Arrhythmias
Disturbances in Heart Rhythm
Arrhythmias are categorized by their speed, rhythm, and origin. A slow heart...
Cardiac Action Potential
The cardiac action potential process involves a series of phases characterized by the movement of ions across the cardiac cell membranes, leading to the depolarization and repolarization of the cardiac myocytes.
Ionic Basis of Cardiac Action Potentials
Dysrhythmias IV: Characteristics of Bradyarrhythmias
ECG Interpretation of Arrhythmias II: Atrial, Junctional and Ventricular Arrhythmias