Adult pulpal diagnosis. I. Evaluation of the positive and negative responses to cold and electrical pulp tests
D D Peters1, J C Baumgartner, L Lorton
1Advanced Education Program in Endodontics, University of Texas Health Science Center at San Antonio 78284-7892, USA.
Abstract:
This study investigated the positive and negative responses of 1488 teeth in 60 patients to two electric pulp testers and a cold thermal pulp test. Three subgroups of known pulpless or pulpally diseased teeth (teeth receiving root canal therapy, teeth with root canal fillings, or teeth with confirmed associated apical radiolucencies) were identified and their responses evaluated separately. Testing was performed on two tooth surfaces, the facio-occlusal and faciocervical, and on all restorations. The gingival tissue of each patient also was tested using both electrical tests. The primary findings were: (a) teeth not responding to cold and either not responding or responding at readings greater than the tissue response to electrical had a high probability of being in the known pulpless or pulpally diseased subgroups; (b) the only false positive responses to cold in the three subgroups were in multirooted teeth with probable vital tissue remaining in at least one canal; and (c) in the three subgroups, if the false positive responses to electrical that responded at levels higher than the patient's tissue response were considered to be negative responses, the difference in false positives between cold and electrical became not statistically significant (p = 0.07).
Related Concept Videos
Assessment of apical pulse
Assessing the apical pulse is a critical nursing procedure, particularly indicated for:
Assessment of radial pulse
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps:
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above the...
Cardiovascular System Abnormal Findings I: Inspection and Palpation
Abnormal findings observed during an inspection
Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation