Related Experiment Video
Updated: Aug 17, 2026

Topical Airway Anesthesia for Awake-endoscopic Intubation Using the Spray-as-you-go Technique with High Oxygen Flow
Published on: January 13, 2017
[Nitrous oxide exposure of operating room personnel in intubation anesthesia]
Introduction:
Epidemiological studies have shown that trace concentrations of inhalation anaesthetics polluting the air of operation theatre could have adverse effects on the personnel's health. Nitrous oxide (N2O) oxidizes vitamin B12 and thus decreases DNA production by inactivation of methionine synthase. Therefore, US and most European health authorities recommend threshold values to protect against potential health risks. These values range from 25 ppm to 100 ppm, expressed as time-weighted averages (TWA). There is a lack of data concerning measurements of trace concentrations under defined conditions. The aim of this study was to quantify levels of N2O in an operating theatre (OT) under modern working environment conditions.
Methods:
Trace concentrations of N2O were determined in the OT at three personnel-related and three potential leakage related points and TWA's were calculated. Trace concentrations of N2O were measured directly by means of a highly sensitive photoacoustic infrared spectrometry analyser. The lower detection limit was 0.03 ppm.
Results:
Values were below 100 ppm TWA at personnel-related locations. NIOSH 25 ppm threshold limit value was exceeded several times. Significant differences between location surgeon and anaesthetist and auxiliary nurse were detected (p < 0.05, Wilcoxon test).
Conclusion:
Exposure to N2O in a climatised OT is determined by several factors: 1. Efficacy of the air-conditioning with 20 changes per hour without recirculation, 2. OT size, 3. low leakage anaesthesia machine, and 4. avoidance of intermittent nitrous oxide supply during induction. Due to these factors, most measured values are below threshold values. In case of other concepts of room design such as ventilation and size, measured values may be higher.
More Related Videos
14:52Recording Brain Electromagnetic Activity During the Administration of the Gaseous Anesthetic Agents Xenon and Nitrous Oxide in Healthy Volunteers
Published on: January 13, 2018
05:46A Novel Inhalation Mask System to Deliver High Concentrations of Nitric Oxide Gas in Spontaneously Breathing Subjects
Published on: May 4, 2021
Related Concept Videos
Inhalational Anesthetics: Overview
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Administering Oxygen by Nasal Cannula
Nasal Cannulas
A nasal cannula is a lightweight tube split into two prongs placed in the nostrils, connected...
Administering Oxygen by Mask
Administering oxygen by mask is a common nursing intervention that provides supplemental oxygen to patients with respiratory distress or chronic lung conditions. This procedure involves delivering oxygen at a specified rate through a face mask connected to an oxygen source.
Equipment
The equipment necessary for this procedure includes:
Endotracheal Intubation I: Procedure
The ET tube comprises various components, including a standard adaptor to attach a bag-valve-mask (BVM) or ventilator, a cuff, a pilot balloon, and radiopaque markings along its length to measure the insertion distance. The tube sizes...
Endotracheal Intubation II: Nursing Management
1. Nursing Care of Patients Before Intubation
Before the endotracheal intubation procedure, nurses play an essential role in ensuring the process goes smoothly. The nurses must be familiar with intubation...