Fracture toughness of human bone under tension
Related Experiment Video
Updated: Oct 24, 2026

Fragility Assessment of Bovine Cortical Bone Using Scratch Tests
Published on: November 30, 2017
T L Norman1, D Vashishth, D B Burr
1Department of Mechanical and Aerospace Engineering, West Virginia University, Morgantown 26505, USA.
Abstract:
The longitudinal fracture toughnesses of human cortical bone were compared to those of bovine cortical bone to test the hypothesis that although human osteonal bone is significantly weaker and more compliant than primary (plexiform) bone, it is not less tough than primary bone. The fracture toughness indices, critical strain energy release rate (Gc) and critical stress intensity factor (Kc), were determined for human Haversian bone and bovine bone under tension (Mode I) loading using the compact tension method. The effects of thickness, crack growth range and anisotropy on fracture indices for slow stable crack growth in cortical bone were determined. Plane strain assumptions required for application of linear elastic fracture mechanics (LEFM) to bone were investigated. Longitudinal oriented fracture toughness tests were used to assess the crack inhibiting effect of human bone microstructure on fracture resistance. Human bone Kc calculated from the stress concentration formula for 2 and 3 mm thick specimens equaled 4.32 and 4.05 MN m-3/2, respectively. Human bone Gc calculated from the compliance method equaled 827 N m-1 for 2 mm thick specimens and 595 N m-1 for 3 mm thick specimens. It was found that crack growth range, thickness and material assumptions affect fracture toughness. Kc calculated from Gc using an anisotropic relation provided the lowest estimate of Kc and equaled 3.31 MN m-3/2 for 2 mm thick specimens and 2.81 MN m-3/2 for 3 mm thick specimens. Both Kc and Gc were significantly reduced after being adjusted to ASTM standard thickness using ratios determined from bovine bone. The fracture toughness of bovine bone relative to human bone ranged from 1.08 to 1.66. This was compared to the longitudinal strength of bovine bone relative to the longitudinal strength of human bone which is approximately equal to 1.5. We found that even though human bone is significantly weaker than bovine bone, relative to its strength, the toughness of human and bovine bone are roughly similar, but the data were not sufficiently definitive to answer the question of which is tougher.
Related Concept Videos
Compact Bone
Compact bone, also called cortical bone, is the denser, stronger of the two types of bone tissue. It is found under the periosteum and in the diaphyses of long bones, where it provides support and protection. The microscopic structural unit of compact bone is called an osteon, or haversian system. Each osteon is composed of concentric rings of calcified...
Fractures: Bone Repair
Minor fractures with no bone displacement are treated by immobilizing the fractured bone using a cast or splint. However, in the case of fractures with displaced bones, the broken bones are repositioned before immobilization to ensure successful healing without deformation and loss of function. The realignment of fractured bone ends is performed through a process called reduction. If the procedure...
Stress-Strain Diagram - Brittle Materials
Tensile Strength Considerations of Concrete
The dimensions and shape of a concrete specimen also...
Behavior of Concrete Under Compressive Load
As the concrete specimen fractures under...
Mechanical Characteristics of Steel
The tension test is fundamental for determining tensile strength. In this test, a steel specimen is stretched using a gripping device until it breaks. The data collected during this test are used to...