Related Experiment Video
Updated: Aug 18, 2026

Optimize Flue Gas Settings to Promote Microalgae Growth in Photobioreactors via Computer Simulations
Published on: October 1, 2013
Defining the relationship of oxygen delivery and consumption: use of biologic system models
D A Lubarsky1, L R Smith, R N Sladen
1Department of Anesthesiology, Duke University Medical Center, Durham, North Carolina 27710, USA.
Abstract:
To determine the most appropriate mathematical description of the relationship between oxygen consumption and oxygen delivery, we compared the statistical validity of a piecewise linear model to two different biologic system models--Michaelis-Menten (MM) kinetics (used for enzyme systems) and the exponential dose-response relationship (used to describe drug administration and induced response). Nine rabbits underwent five incremental steps of normovolemic hemodilution to progressively decrease DO2. VO2 was measured concurrently by a metabolic gas monitor. All three models (piecewise linear, Michaelis-Menten, and exponential) provided a very close population curve fit to the data points (r2 = 0.88, 0.91, and 0.92). However, there were significant differences in maximum predicted VO2 (VO2max)--6.8, 9.9, 7.2 ml O2.kg-1.min-1 (P < 0.0002)--and a wide range in the model-specific parameters for individual rabbits (critical DO2 6.5-11.8 ml O2.kg-1.min-1, Km 4.2-11.4 ml O2.kg-1.min-1, and kappa 0.12-0.23 ml O2-1.kg.min). In the curvilinear models, average and population parameters were not significantly different. However, in the piecewise linear model, population critical DO2 (10.9 ml O2.kg-1.min-1) was 30% more than the average critical DO2 (8.4 ml O2.kg-1.min-1) for the nine rabbits (P < 0.005). VO2max values predicted by the piecewise linear and exponential dose-response model were more consistent with those in previous publications than was the higher VO2max predicted by the MM model. The difference in the average versus population critical DO2 in the piecewise linear model meant that population modeling was inaccurate because it yielded a critical DO2 higher than that demonstrated by eight of nine individual rabbits.(ABSTRACT TRUNCATED AT 250 WORDS)
Related Concept Videos
Respiration and Gaseous Exchange
Respiration involves the exchange of gases, especially oxygen (O2) and carbon dioxide (CO2), between the alveoli and body cells, a process facilitated by blood circulation. As a result, the cardiovascular system, which involves the...
Oxygen Transport in the Blood
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
Pharmacokinetic Models: Overview
There are three primary types of models: empirical, compartment, and physiological. Empirical models, with minimal assumptions,...
Model Approaches for Pharmacokinetic Data: Physiological Models
Pharmacokinetic Models: Comparison and Selection Criterion