Related Experiment Video
Updated: Jul 21, 2026

Assessing Cerebral Autoregulation via Oscillatory Lower Body Negative Pressure and Projection Pursuit Regression
Published on: December 10, 2014
Prospective assessment of an artificial neural network for the detection of peripheral vascular disease from lower
Abstract:
The diagnostic performance of an artificial neural network pulse classification system for the detection of peripheral vascular disease was investigated prospectively. Lower limb photoelectric plethysmographic pulses, and Doppler ankle/brachial pressure index (ABPI) measurements (pre- and post-exercise) were obtained from 200 patients referred to a vascular investigation laboratory. A single toe pulse was processed and used as input data to a neural network which had been trained previously with a set of pulses from 100 legs. The neural network outputs represented the diagnostic arterial disease classifications defined by the ABPI. From the 200 patients entered prospectively, 266 legs were available for neural network assessment. A network sensitivity of 92% and specificity of 63% were achieved with a diagnostic accuracy of 80%. By using a higher confidence for the classification decision a small, but insignificant overall improvement was obtained. When a borderline classification was introduced 100% sensitivity and 100% negative predictive value were obtained, though 31% of legs were unclassifiable. Nevertheless, the very high sensitivity and negative predictive value could make this quick and simple technique the one of choice for the first stage in screening large numbers of subjects.
More Related Videos
07:25Predicting Amputation using Local Circulating Mononuclear Progenitor Cells in Angioplasty-treated Patients with Critical Limb Ischemia
Published on: September 22, 2020
04:44Near-Infrared Spectroscopy During Reactive Hyperemia for the Assessment of Lower Limb Vascular Function
Published on: March 22, 2024
Related Concept Videos
Pulse amplitude and quality
A weak or absent pulse may indicate reduced cardiac output or poor left ventricular contraction, which can be signs of cardiovascular dysfunction or...
Pulse Assessment Sites
Assessment of radial pulse
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps:
Special considerations while measuring pulse
Pulse
The pulse serves as a clinical indicator...
Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation