Related Experiment Video
Updated: Aug 19, 2026

Occlusion of the Great and Small Saphenous Vein Using Copolymeric Glue Based on N-Butyl Cyanoacrylate and Methacryloxy Sulfolane
Published on: December 9, 2022
Percutaneous transluminal angioplasty of infrainguinal vein graft stenosis: long-term outcome
P Dunlop1, K Varty, T Hartshorne
1Department of Surgery, Leicester Royal Infirmary, UK.
Insights
Percutaneous transluminal angioplasty (PTA) effectively treats infrainguinal vein graft stenosis initially. However, a high restenosis rate, particularly in distal grafts, necessitates further investigation into optimal management strategies.
Area of Science:
- Vascular Surgery
- Interventional Radiology
Background:
- Infrainguinal vein graft stenosis is a significant complication impacting graft patency.
- Early detection through graft surveillance is crucial for timely intervention.
Purpose of the Study:
- To evaluate the long-term outcomes of infrainguinal vein graft stenosis treated with percutaneous transluminal angioplasty (PTA) as the primary therapy.
- To identify factors associated with restenosis after PTA.
Main Methods:
- Prospective study of 33 infrainguinal vein graft stenoses treated with PTA.
- Follow-up duration ranged from 18 to 56 months (median 39 months).
- Analysis of restenosis rates based on graft location and type.
Main Results:
- Successful treatment with a single PTA in 19 out of 33 cases.
- Recurrence of stenosis observed in 14 cases at a median of 8.5 months post-PTA.
- Higher restenosis rates were noted in the distal third of grafts (P=0.002) and in situ vein grafts (P=0.03).
Conclusions:
- Single-session PTA can achieve initial success in managing infrainguinal vein graft stenosis.
- Distal graft location and in situ vein grafts are associated with increased risk of restenosis.
- Optimal management strategies for recurrent infrainguinal vein graft stenosis require further research.
Abstract:
The aim of this prospective study was to examine the long-term outcome of infrainguinal vein graft stenosis managed by percutaneous transluminal angioplasty (PTA) as first-line treatment. Thirty-three infrainguinal vein graft stenoses detected by graft surveillance during a 44-month period were treated initially by PTA. The median (range) follow-up after angioplasty was 39 (18-56) months. Although 19 stenoses were successfully treated by a single PTA, 14 stenoses recurred at a median (range) interval of 8.5 (1-39) months. Restenosis occurred more frequently in the distal third of a graft (P = 0.002) compared with that in the proximal or mid-grafts, and restenosis was more common in in situ than reversed vein grafts (P = 0.03). It is concluded that infrainguinal vein graft stenoses were successfully treated by single PTA. There was, however, a high restenosis rate after angioplasty of stenosis in the distal third of a vein graft and, while approximately one third of such stenoses can be treated by a single PTA, the optimal management of recurrent stenosis requires further investigation.
More Related Videos
13:48Reduction of Radiation Exposure during Endovascular Treatment of Peripheral Arterial Disease Combining Fiber Optic RealShape Technology and Intravascular Ultrasound
Published on: April 21, 2023
06:59Catheter-based Endovascular Angioplasty for Fibrosing Mediastinitis-associated Pulmonary Vein Stenosis
Published on: August 26, 2025
Related Concept Videos
Peripheral Artery Disease III: Interprofessional Care
Peripheral Artery Disease V: Postoperative Nursing Management
Varicose Veins II: Diagnostic Studies and Interprofessional Care
Hemodialysis I: Introduction