American National Standard for nonautomated sphygmomanometers. Summary report
L M Prisant1, B S Alpert, C B Robbins
1Department of Medicine, Medical College of Georgia, Augusta, USA.
Abstract:
The Association for the Advancement of Medical Instrumentation develops voluntary standards for medical devices so that manufacturers might provide information on their product and basic safety and performance criteria that should be considered in qualifying the instrument for clinical use. American National Standards are generated through a consensus process by committees of experts in research, development, and design from user, industry, and government communities. Draft standards are made available for public review and become American National Standards after review by the American National Standards Institute. This report is a summary of the American National Standard that establishes both the safety and performance requirements of pneumatic and other nonautomated sphygmomanometers (especially mercury gravity and aneroid sphygmomanometers) used in the indirect measurement of blood pressure. This standard was developed by a consensus panel from academia, industry, and government; it updates the previous standard approved by the American National Standards Institute in 1986. This summary report does not cover all of the provisions of the revised 1994 American National Standard, thus users, researchers, and instrument designers should refer to the standard for detailed requirements.
Related Concept Videos
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Assessment of blood pressure in brachial artery(two-step method)
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Pre-Procedural Guidelines for Assessing Blood Pressure