A simple method to detect expiratory flow limitation during spontaneous breathing
Related Experiment Video
Updated: Oct 9, 2026

Expired CO2 Measurement in Intubated or Spontaneously Breathing Patients from the Emergency Department
Published on: January 29, 2011
N G Koulouris1, P Valta, A Lavoie
1Meakins-Christie Laboratories, McGill University, Montreal, Quebec, Canada.
Abstract:
Patients with severe chronic obstructive pulmonary disease (COPD) often exhale along the same flow-volume curve during quiet breathing as during a forced expiratory vital capacity manoeuvre, and this has been taken as indicating flow limitation at rest. To obtain such curves, a body plethysmograph and the patient's co-operation are required. We propose a simple technique which does not entail these requirements. It consists in applying negative pressure at the mouth during a tidal expiration (NEP). Patients in whom NEP elicits an increase in flow throughout the expiration are not flow-limited. In contrast, patients in whom application of NEP does not elicit an increase in flow during most or part of the tidal expiration are considered as flow-limited. Using this technique, 26 stable COPD patients were studied sitting and supine. Eleven patients were flow-limited both seated and supine, eight were flow-limited only when supine, and seven were not flow-limited either seated or supine. Only 5 of 19 patients who were flow-limited seated and/or supine had severe ventilatory impairment (forced expiratory volume in one second (FEV1) < 40% predicted). We conclude that the NEP technique provides a simple, rapid, and reliable method for detection of expiratory flow limitation in spontaneously breathing subjects, which does not require the patient's co-operation, and can be applied in different body positions both at rest and during muscular exercise. Our results also indicate a high prevalence of flow limitation in COPD patients at rest, particularly when supine.
Related Concept Videos
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this principle...
Respiratory Volumes and Capacities I
Respiratory Volumes
Tidal Volume (TV) Tidal volume (TV) is the air inhaled or exhaled in a...
Assessment of Airway, Skin Color, and Use of Accessory Muscles
Introduction
The initial evaluation of a patient's respiratory system...
Assessment of Ventilation II: Respiratory Depth and Rhythm
Respiratory depth measures the volume of air inhaled or exhaled during a breath. It can vary from shallow to deep and typically remains consistent when a person is at rest or asleep. Occasionally, individuals will automatically inhale deeply, known as sighing, which inflates the lungs with more air than normal breathing.
To assess respiratory depth, observe the degree of chest excursion or movement:
Physical Assessment of the Respiratory Tract II: Inspection
Chest Configuration
The chest configuration can...