Related Experiment Video
Updated: Aug 12, 2026

Post Column Derivatization Using Reaction Flow High Performance Liquid Chromatography Columns
Published on: April 26, 2016
Determination of (+)-catechin in plasma by high-performance liquid chromatography using fluorescence detection
1Department of Pharmaceutics, School of Pharmacy, Taipei Medical College, Taiwan.
Abstract:
A high-performance liquid chromatographic method, using fluorescence detection, was developed for the determination of (+)-catechin in rabbit plasma. The procedure involved the precipitation of plasma protein using acetonitrile, followed by solid-phase adsorption onto alumina. After washing with water and methanol, the residue was vortex-mixed with perchloric acid solution to release the adsorbed (+)-catechin. Separation was performed on a reversed-phase column using an eluent consisting of phosphoric acid solution with 12% acetonitrile. The excitation and emission wavelengths were set at 280 and 310 nm, respectively. The retention times for (+)-catechin and the internal standard (deoxyhigenamine) were 6.87 and 8.47 min respectively, without any interference. Validations of accuracy and precision were satisfactory in both within- and between-run assays. All coefficients of variance were less than 6% and mean relative errors were within +/- 3.75%. The average recovery was 73.77%. The limit of detection and quantitation were 1 ng and 0.02 micrograms/ml, respectively. Application of this method was successfully assessed by intravenous administration of a 15 mg/kg dose of (+)-catechin in rabbits. This new method provides a simple, specific and sensitive determination for (+)-catechin in rabbit plasma and is suitable for pharmacokinetic studies.
More Related Videos
13:35A Convenient Method for Extraction and Analysis with High-Pressure Liquid Chromatography of Catecholamine Neurotransmitters and Their Metabolites
Published on: March 1, 2018
14:39Semi-Targeted Ultra-High-Performance Chromatography Coupled to Mass Spectrometry Analysis of Phenolic Metabolites in Plasma of Elderly Adults
Published on: April 22, 2022
Related Concept Videos
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Gas Chromatography: Types of Detectors-II
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
High-Performance Liquid Chromatography: Instrumentation
High-Performance Liquid Chromatography: Types of Detectors