Related Experiment Video
Updated: Aug 19, 2026

Programmed Electrical Stimulation in Mice
Published on: May 27, 2010
Characterization of return cycle responses predictive of successful pacing-mediated termination of ventricular
D J Callans1, B G Hook, R L Mitra
1Clinical Electrophysiology Laboratories, Philadelphia Heart Institute, Presbyterian Medical Center, Pennsylvania 19104.
Objectives:
The purpose of this study was to characterize response patterns during overdrive pacing that predict successful termination of ventricular tachycardia.
Background:
Overdrive pacing during ventricular tachycardia typically results in entrainment at slow pacing rates and in termination or acceleration at faster rates. The factors that determine the critical paced cycle length that results in tachycardia termination have not been extensively studied.
Methods:
Ventricular tachycardias in 14 patients with coronary artery disease were studied with overdrive pacing at several cycle lengths. Return cycles were measured after each additional paced beat at each paced cycle length. The return cycle responses during pacing trials that resulted in tachycardia termination and those that resulted in entrainment were compared.
Results:
Three return cycle responses were identified: flat, plateau and increasing. Twenty trials of overdrive pacing resulted in tachycardia termination; all were characterized by an increase in the return cycle with the delivery of each successive beat in the pacing drive until the tachycardia terminated (increasing response). Thirty-four pacing trials resulted in entrainment and not termination; these were characterized either by a constant return cycle (flat response) or an initial increase in return cycle followed by a longer, constant return cycle (plateau response) with the delivery of additional paced beats. The longest paced cycle length that resulted in tachycardia termination correlated with the relative refractory period of the circuit, defined as the tachycardia cycle length minus the fully excitable gap (r2 = 0.764, p = 0.0001). Tachycardia termination was not observed unless the paced cycle length was shorter than the relative refractory period of the circuit.
Conclusions:
The critical paced cycle length that causes termination of ventricular tachycardia depends on the relative refractory period of the circuit because this factor determines whether the nth + 1 beat of the pacing drive will encounter partially recovered tissue. These data provide insights into the mechanism of pacing-mediated tachycardia termination and entrainment and are applicable to the development of improved antitachycardia pacing algorithms.
Related Concept Videos
Electrophysiology of Normal Cardiac Rhythm
Disturbances in Heart Rhythm
Arrhythmias are categorized by their speed, rhythm, and origin. A slow heart...
Cardiac Action Potential
The cardiac action potential process involves a series of phases characterized by the movement of ions across the cardiac cell membranes, leading to the depolarization and repolarization of the cardiac myocytes.
Ionic Basis of Cardiac Action Potentials
Dysrhythmias II: Classification of Tachyarrhythmias
Dysrhythmias III: Characteristics of Dysrhythmias
ECG Interpretation of Arrhythmias II: Atrial, Junctional and Ventricular Arrhythmias