Related Experiment Video
Updated: Aug 12, 2026

A Dual Tracer PET-MRI Protocol for the Quantitative Measure of Regional Brain Energy Substrates Uptake in the Rat
Published on: December 28, 2013
The limitations of 113Inm for plasma volume measurement
Abstract:
Previous authors have claimed that 113InmCl3 is a valid tracer for plasma volume measurement. However, careful measurements in haematologically normal volunteers and in rabbits, using 125I-labelled human serum albumin as a reference tracer, show that the results obtained with 113Inm-chloride, -citrate or -transferrin consistently over-estimate the plasma volume and are probably no better than can be predicted from the height and weight of the subject.
More Related Videos
10:21Continuous Blood Sampling in Small Animal Positron Emission Tomography/Computed Tomography Enables the Measurement of the Arterial Input Function
Published on: August 8, 2019
08:23Quantitative Measure of Lung Structure and Function Obtained from Hyperpolarized Xenon Spectroscopy
Published on: November 10, 2023
Related Concept Videos
Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview
Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences
Volume of Distribution