Related Experiment Videos
Rectangular field of view for dynamic MR imaging of sellar and parasellar regions
Y Korogi1, M Takahashi, T Hirai
1Department of Radiology, Kumamoto University School of Medicine, Japan.
Radiation Medicine
|July 1, 1994
Abstract:
The effectiveness and quality of a rectangular field of view (R-FOV) were compared with those of a square FOV (S-FOV) in dynamic MR study of sellar regions. Cranial nerves in the cavernous sinus were identified more clearly with R-FOV. The image quality grading of R-FOV was significantly superior to that of S-FOV.