Effect of component-relative-entropy on the discrimination of simultaneous tone complexes
1Department of Communicative Disorders, University of Wisconsin, Madison 53706.
Abstract:
Results are reported from a number of experiments investigating the effects of stimulus uncertainty on the discrimination of simultaneous multitone complexes. With few exceptions the data were well described by a model in which average threshold for the detection of a change in one or more components varies with the components' relative entropy (CoRE) in the complex [R.A. Lutfi, J. Acoust. Soc. Am. 94, 748-758 (1993)]. In different experiments, thresholds for the detection of a change in target level were found to be linearly related to CoRE for manipulations in the number of targets, the number of context tones, and the relative degree of level perturbation on tones from trial to trial. The slopes of the functions did not change with measures taken at different points on the psychometric function, and in most cases were close to the theoretical value of b = -1.0, as predicted by strict application of the model. Also as predicted (but for the exception of one listener) increasing the level of the target beyond that of the context had little or no effect on threshold. A correlational analysis of the trial-by-trial data revealed a tendency of listeners to give negative weight to frequencies immediately above the target, and to adjust weights in response to changes in the relative degree of level perturbation. Though inconsistent with the basic premise of the model, the variation in weights was not so great as to materially affect the predictions for mean thresholds.
Related Concept Videos
¹H NMR: Interpreting Distorted and Overlapping Signals
As Δν decreases and the signals move closer, the doublets appear increasingly distorted. The intensities of the inner lines increase at the cost of those of the outer lines as the signals are slanted or...
IR Spectrum Peak Splitting: Symmetric vs Asymmetric Vibrations
¹H NMR Signal Integration: Overview
Expected Frequencies in Goodness-of-Fit Tests
Difference from Background: Limit of Detection
The LOD indicates the presence or absence...
Interference: Path Lengths
Two special sources may be considered when they are in phase. This can be easily achieved by feeding the two sources from the same source. An example would be synchronizing the two speakers by feeding them with the same source, such as the sound waves produced by a tuning fork. This setup ensures that the two sources have the same frequency and are...


