Comparison of a conventional probe with electronic and manual pressure-regulated probes
D A Perry1, E J Taggart, A Leung
1Department of Dental Public Health and Hygiene, School of Dentistry, University of California, San Francisco.
Abstract:
We compared the accuracy, consistency, time, comfort, and cost of probing with a conventional hand probe (CP) with 3-mm banded markings, a manual pressure-regulated probe (MP), and two electronic probes (IP and FP). Twenty (20) examiners used all four probes on a test block to determine accuracy; measurements compared favorably to the reference block. Two calibrated examiners probed the Ramfjord teeth of 10 periodontal patients on maintenance regimens, six sites per tooth (n = 708), with all four probes; measurements were repeated after one week. Wilcoxon signed-rank test showed the CP measured more deeply (P < 0.0001) than MP, FP, and IP with mean differences of 0.40, 0.67, and 0.58 respectively. MP measured more deeply (P < 0.001) than FP and IP, with mean differences of 0.27 and 0.18 mm. There was no difference between FP and IP. Time (min:sec) required by one examiner to perform full mouth probing on six subjects (minimum of 26 teeth each) was CP = 3:59; MP = 4:18; FP = 6:16; and IP = 7:23. Subjects rated FP and IP as slightly more uncomfortable than CP or MP. Cost per 1,000 uses was computed based on available data. The IP and FP took longer to perform and cost more per procedure than did the CP and MP. Spearman rank-order correlation revealed that only probe depths measured by CP and MP were well correlated (rs = 0.67). Although some statistically significant differences were found between probes, no differences were considered to be of clinical significance when probing periodontally healthy or maintenance patients.(ABSTRACT TRUNCATED AT 250 WORDS)
Related Concept Videos
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Pressure Gauges
Measurement of Fluid Pressure
A basic form of manometer is the piezometer, a vertical tube open at the top and filled with the same...