Related Experiment Video
Updated: Jan 20, 2026

Development of a Neonatal Piglet Acute Lung Injury Model Recreating the Early Environment of Preterm Infant Lungs
Published on: October 31, 2025
Overestimation of serum vancomycin concentrations using a fluorescence polarization immunoassay (Tdx) in preterm
1University of Texas College of Pharmacy, Austin.
Abstract:
Serum vancomycin concentrations determined by fluorescence polarization immunoassay (FPIA) with a specific high-performance liquid chromatography (HPLC) method in preterm neonates were compared. Preterm neonates (< 38 weeks gestational age) requiring vancomycin therapy and serum vancomycin concentration monitoring were enrolled. Peak serum vancomycin concentration samples were collected and independently analyzed by FPIA and HPLC. Multivariate and stratified data analysis was done with mean absolute error and mean percent error as dependent variables and independent variables as postconceptional age, postnatal age, gestational age, weight, and duration of therapy to characterize the findings. A total of 15 paired vancomycin concentrations were analyzed from neonates with a mean gestational age of 30 +/- 4 weeks. The mean percentage error of FPIA versus HPLC vancomycin concentrations was 18.1 +/- 11.1% and the mean absolute error was 3.7 +/- 2.0 mg/l. Postconceptional age, weight, and time from initiation of therapy to sample collection were independent variables which best characterized the overestimation of FPIA vancomycin concentrations. The FPIA vancomycin assay method overestimated actual vancomycin concentrations in preterm neonates. Preterm neonates less than 30 weeks postconceptional age, less than 1,200 g body weight, and duration of therapy greater than 48 h prior to concentration determination had the greatest difference in FPIA and HPLC results. Significant error in pharmacokinetic parameter estimations and dosage adjustments is possible when vancomycin concentrations are determined by FPIA.
More Related Videos
Related Concept Videos
08:58Development of a Neonatal Piglet Acute Lung Injury Model Recreating the Early Environment of Preterm Infant Lungs
07:13Fluorescent Lateral Flow Immunoassay Based on Quantum Dots Nanobeads
14:43A Novel Method for Involving Women of Color at High Risk for Preterm Birth in Research Priority Setting
06:27Transcutaneous Microcirculatory Imaging in Preterm Neonates
11:17Monitoring Changes in Membrane Polarity, Membrane Integrity, and Intracellular Ion Concentrations in Streptococcus pneumoniae Using Fluorescent Dyes
10:12A Sensitive and Specific Quantitation Method for Determination of Serum Cardiac Myosin Binding Protein-C by Electrochemiluminescence Immunoassay

