Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Experiment Videos

Computer analysis of auditory brainstem responses by using advanced pattern recognition

T K Grönfors1

  • 1Dept. of Computer Science and Applied Mathematics, Univ. of Kuopio, Finland.

Journal of Medical Systems
|August 1, 1994
PubMed
Summary

This study presents an automated system for detecting auditory brainstem responses (ABRs). The system accurately identifies key peaks in ABR signals, achieving 90% accuracy in clinical tests.

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

On digital filtering of auditory brainstem responses.

Medical progress through technology·1993
See all related articles

Area of Science:

  • Neuroscience
  • Biomedical Engineering
  • Signal Processing

Background:

  • Auditory Brainstem Responses (ABRs) are crucial for assessing auditory pathway function.
  • Automatic detection of ABR peaks simplifies clinical analysis.
  • Existing methods may lack accuracy or require manual intervention.

Purpose of the Study:

  • To develop and validate an automated system for detecting auditory brainstem responses (ABRs).
  • To accurately identify the pedestal peak and subsequent Peak V in filtered ABR signals.
  • To achieve high accuracy in ABR peak detection using clinical data.

Main Methods:

  • A multistage automatic peak detection process was implemented.
  • The system focuses on identifying the pedestal peak within the ABR signal.

Related Experiment Videos

  • Specialized validation stages were incorporated to confirm the presence of a real response.
  • Peak V detection follows successful validation.
  • Main Results:

    • The automated system demonstrated high accuracy in detecting ABR peaks.
    • The system achieved 90% accuracy when tested with random clinical material.
    • The multistage process effectively filtered and identified relevant peaks.

    Conclusions:

    • The developed automated system provides a reliable method for ABR peak detection.
    • The system's 90% accuracy suggests its potential for clinical application.
    • Automated ABR analysis can enhance efficiency and consistency in audiological assessments.