Tilt Testing with Combined Lower Body Negative Pressure: a "Gold Standard" for Measuring Orthostatic Tolerance
Published on: March 21, 2013
Ambulatory blood pressure monitoring
1Department of Medicine for the Elderly, James Connolly Memorial Hospital, Blanchardstown, Dublin, Ireland.
Abstract:
Non-invasive measurement of blood pressure in ambulatory humans began in the 1960s. Ambulatory devices have been modified over the years and are now pocket-sized, with almost noiseless pumps. Their accuracy must be validated by independent laboratories using a standardised protocol. Twenty-four-hour ambulatory monitoring offers considerable advantages over conventional measurement, including avoidance of error associated with conventional measurement, elimination of white-coat effect and the provision of a series of blood pressure readings over the time period rather than a one-off measurement. In clinical practice, 24-hr monitoring provides valuable assistance in both the diagnosis and treatment of hypertension, in particular, in the selection of drug and dosage regimen. In the research setting, 24-hr monitoring plays an important role in establishing dose-response relationships and the duration of action of new drugs. It also has a role in the design of antihypertensive trials by ensuring that those with white-coat hypertension are excluded and by reducing the number of subjects necessary for recruitment. Although 24-hr ambulatory blood pressure is a better predictor of target organ damage, definitive evidence as to whether it is a better predictor of prognosis in hypertension awaits the results of longitudinal studies, which are now underway.
Related Concept Videos
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Assessing Blood pressure in the Leg
Preparation:
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Pre-Procedural Guidelines for Assessing Blood Pressure