Related Experiment Video
Updated: Aug 8, 2026

Capsular Serotyping of Streptococcus pneumoniae by Latex Agglutination
Published on: September 25, 2014
Reduction of antigenic protein levels in latex gloves after gamma irradiation
B D Zehr1, S Gromelski, D Beezhold
1Guthrie Research Institute, Sayre, PA 18840.
Abstract:
Gamma irradiation is currently the method most commonly used to sterilize surgical gloves. In this study, the effect of gamma irradiation on antigenic proteins in latex gloves was examined. Protein extraction and quantitation were carried out using latex gloves before and after sterilization. Antigenic protein levels were determined by an ELISA assay specific for latex proteins (LEAP). LEAP analysis revealed a significant decrease after gamma-irradiation sterilization. This observation may partially explain the lower levels of extractable antigenic proteins found in sterile surgical gloves compared with nonsterile examination gloves. However, gamma irradiation was less effective than autoclave sterilization in reducing protein levels.