Ultrasonic Assessment of Myocardial Microstructure
Published on: January 14, 2014
Attenuation deforms time-intensity curves during contrast echocardiography: implications for assessment of mean
A R Jayaweera1, S Ismail, S Kaul
1Cardiovascular Division, University of Virginia, Charlottesville 22908.
Abstract:
The mean transit rate of microbubbles of air obtained from time-intensity curves during contrast echocardiography can be used to evaluate flow through a vascular system, provided the volume of distribution of the system remains constant. We hypothesized that attenuation commonly associated with contrast echocardiography distorts the time-intensity curves, producing an error in the estimation of the mean transit rate of the microbubbles. The purpose of this study was to characterize this distortion with computer simulations and to study the effect of attenuation on the estimation of mean transit rate in an in vitro experiment. We also sought to determine if removing the data points from the time-intensity plots that visually can be attributed to attenuation before curve fitting can minimize the error in the estimation of mean microbubble transit rate. In both computer simulations and experimentally acquired in vitro data, attenuation distorted the time-intensity curves, producing an underestimation of mean microbubble transit rates. The mean microbubble transit rate decreased with an increase in microbubble concentration. Removing the points that visually were attributed to attenuation before curve fitting did not correct this error completely in the computer-simulated data and failed to correct it at all in the experimental data. These results have major practical implications in assessing mean microbubble transit rates during contrast echocardiography.
More Related Videos
11:04Quantification of Global Diastolic Function by Kinematic Modeling-based Analysis of Transmitral Flow via the Parametrized Diastolic Filling Formalism
Published on: September 1, 2014
09:05Transthoracic Speckle Tracking Echocardiography for the Quantitative Assessment of Left Ventricular Myocardial Deformation
Published on: October 20, 2016
Related Concept Videos
Imaging Studies for Cardiovascular System I:Echocardiography
Indications: Echocardiography is utilized to diagnose heart failure, valve disorders, and myocardial infarction. It also assesses cardiac structures' size, shape, and motion, evaluates...
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for diagnosing...