Related Experiment Video
Updated: Aug 14, 2026

Establishing Intracranial Brain Tumor Xenografts With Subsequent Analysis of Tumor Growth and Response to Therapy using Bioluminescence Imaging
Published on: July 13, 2010
Efficacy of Imagent BP at 1.5ml/kg in a rabbit liver tumor model
K G Baker1, R Wrigley, H B Saunders
1MRI Institute, University of California, San Diego Medical Center 92103.
Abstract:
We have shown using a Vx2 rabbit model that 3 and 5ml/kg of perflubron emulsion were highly effective in imaging liver tumors. The results from preliminary clinical trials suggested that should the infusion rate be increased, a 1.5ml/kg may be efficacious. This study determined whether 1.5ml/kg given as a bolus IV would be efficacious to image liver tumors using a Vx2 rabbit model. Vx2 tumors were implanted in 5 NZW rabbits, CT of the liver was performed during held expiration at 80kV and 800mAS, before and shortly after 1.5ml/kg Imagent BP (ImBP), again at 30 minutes and 3 days. Regions of interest (ROIs) were drawn over the CT image of the spleen, liver, inferior vena cava, and tumor, CT# obtained and average enhancement of each tissue calculated at each time point. 4 animals had tumors .5cm or greater. Precontrast, tumors were faintly seen on CT. Blood was brighter than liver shortly after infusion and isointense with liver at 30 minutes. Tumors did not enhance following contrast. Except for the liver and spleen, all tissues returned to baseline on the 3rd day. Therefore a clinical trial to determine the efficacy of 1.5ml/kg ImBP to image the liver is warranted.

