Nontraumatic pediatric musculoskeletal MR imaging: comparison of conventional and fast-spin-echo short inversion time
E Weinberger1, D W Shaw, K S White
1Department of Radiology, University of Washington School of Medicine, Seattle.
Purpose:
To compare conventional short inversion time inversion-recovery (STIR) with fast spin-echo (FSE) STIR techniques to evaluate suspected nontraumatic musculoskeletal abnormalities.
Materials And Methods:
Thirty STIR and FSE-STIR examinations in 26 pediatric patients with suspected nontraumatic musculoskeletal abnormalities were prospectively evaluated. Qualitative (subjective) and quantitative (five-point rank score) analyses of the images were performed.
Results:
FSE-STIR was faster than STIR (mean, 2 minutes 25 seconds and 6 minutes 35 seconds, respectively). Fat suppression was slightly better with STIR. Image degradation due to motion was judged similar. Lesion contrast to muscle was slightly better with STIR than FSE-STIR, and lesion contrast to fat was equivalent. Qualitatively, lesion conspicuity was similar: All lesions were seen with both techniques.
Conclusion:
FSE-STIR can replace STIR when an inversion-recovery fat-suppression sequence is desired. Considerable imaging time is saved.
Related Concept Videos
Magnetic Resonance Imaging
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies for Cardiovascular System IV: CMRI
Imaging Studies IV: Magnetic Resonance Imaging