Intracorporeal oxygenation

P D Richardson1

  • 1Department of Engineering and Physiology, Brown University, Providence, Rhode Island 02912.

Artificial Organs
|November 1, 1994
PubMed
Summary
This summary is machine-generated.

Designing intracorporeal oxygenators requires balancing high gas transfer rates with low blood flow resistance. Further research is needed for biological tolerance, manufacturability, and long-term function of these critical medical devices.

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Ultrasound surveillance for hepatocellular carcinoma: service evaluation of a radiology-led recall system in a tertiary-referral centre for liver diseases in the UK.

Clinical radiology·2017
Same author

A classic collaboration: Michael Davies on plaque vulnerability.

Atherosclerosis·2011
Same author

Flow instability and wall shear stress variation in intracranial aneurysms.

Journal of the Royal Society, Interface·2009
Same author

Discussion of paper by w. H. King., jr.: the use of resonating devices to make small mass measurements.

Bulletin of the New York Academy of Medicine·2009
Same author

Combined effects of pulsatile flow and dynamic curvature on wall shear stress in a coronary artery bifurcation model.

Journal of biomechanics·2005
Same author

Targeted gene correction strategies.

Current opinion in molecular therapeutics·2001

Area of Science:

  • Biomedical Engineering
  • Medical Device Design

Background:

  • Intracorporeal oxygenators are crucial for physiological support.
  • Current designs face significant challenges in achieving adequate gas exchange within physical constraints.

Purpose of the Study:

  • To identify the primary design challenges for intracorporeal oxygenators.
  • To outline the key areas requiring further development for effective device implementation.

Main Methods:

  • Analysis of existing intracorporeal oxygenator design principles.
  • Identification of critical performance parameters and limitations.

Main Results:

  • The primary challenge is optimizing gas transfer rates against blood flow resistance within limited space.

Related Experiment Videos

  • Key unresolved issues include biocompatibility, manufacturability, and device longevity.
  • Conclusions:

    • Effective intracorporeal oxygenator design necessitates overcoming significant engineering and biological hurdles.
    • Future development must focus on improving gas exchange efficiency, ensuring blood compatibility, and enabling prolonged functional use.