Related Experiment Video
Updated: Jul 31, 2026

Quantitative Autonomic Testing
Published on: July 19, 2011
Inspiratory fall in systolic pressure in normal and asthmatic subjects
M D Goldman1, M Mathieu, J M Montely
1Medical College of Pennsylvania, Philadelphia.
Abstract:
We used a noninvasive monitor of arterial pressure to determine whether respiratory changes in arterial pressure were closely correlated with airflow obstruction in asthmatic patients during bronchial challenge with methacholine. To validate the noninvasive measurement of respiratory changes in arterial pressure, a preliminary study in 6 subjects with normal cardiovascular and respiratory systems was done during cardiac catheterization for suspected coronary artery disease. There were no significant differences between inspiratory falls in systolic pressure measured noninvasively and those measured from intraaortic pressure. In 11 otherwise healthy asthmatic patients we measured finger arterial pressure, end-expiratory lung volume (FRC), and forced expired volume (FEV1) during baseline and bronchial challenge in the supine posture. Finger arterial pressure was also measured in 11 normal control subjects seated and supine. Normal subjects had an inspiratory fall in systolic pressure (IFSP) of 3.2 mm Hg supine and 5.1 mm Hg seated (p < 0.01). Asthmatic patients when bronchodilated (seated FEV1 = 83 +/- 7% of predicted) had an IFSP of 5.9 mm Hg supine (p < 0.01 compared with supine normal subjects). During bronchial challenge (average fall in FEV1 = 22%), IFSP increased to 16.1 mm Hg (p < 0.001 compared with baseline). In asthmatic subjects, there was a significant correlation between IFSP and FEV1 (mean r = -0.92 +/- 0.05, p < 0.01), and the average change in IFSP/change in FEV1 was -0.38 mm Hg per percentage change in FEV1. During subsequent bronchodilation, IFSP decreased with a similar time course as relaxation of airway smooth muscle, assessed by the breath-to-breath fall in FRC.(ABSTRACT TRUNCATED AT 250 WORDS)
Related Concept Videos
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Blood Pressure
Measurement of Blood Pressure
Pressure Relationships in Thoracic Cavity
Breathing Mechanisms
Both intra-alveolar and intrapleural pressures rely on specific lung properties. The ability to breathe—allowing air to enter the lungs during...
Pulmonary Ventilation: Inhalation
Boyle's law becomes particularly pertinent when examining respiratory...

