Assessment of disease severity in parkinsonism with fluorine-18-fluorodeoxyglucose and PET
D Eidelberg1, J R Moeller, T Ishikawa
1Department of Neurology, North Shore University Hospital/Cornell University Medical College, Manhasset, NY 11030.
Unlabelled:
Fluorine-18-fluorodeoxyglucose (FDG) and PET have been used to identify an abnormal regional metabolic covariance pattern in Parkinson's disease (PD). To examine the potential use of this covariance pattern as a metabolic imaging marker for PD, we describe the Topographic Profile Rating (TPR), which is a method for calculating subject scores for this pattern in individual PD patients. We then assess the relationship between these metabolic measures and objective independent disease severity ratings.
Methods:
Two independent groups of PD patients were studied with FDG-PET. Group A consisted of 23 patients (mean age 60.2 +/- 12.2; mean Hoehn and Yahr stages 2.4 +/- 1.3) and Group B had 14 patients (mean age 49.0 +/- 12.1; mean Hoehn and Yahr stage 3.2 +/- 1.2). The regional cerebral metabolic rates for glucose (rCMRGlc) in all patients in each group were measured. TPR was used to calculate subject scores for the disease-related covariance pattern on a patient-by-patient basis.
Results:
In both PD patient groups, subject scores correlated with Hoehn and Yahr disease severity ratings (Group A: r = 0.59, p < 0.004; Group B: 0.57, p < 0.04), quantitative ratings for bradykinesia (Group A: r = 0.63, p < 0.002; Group B: r = 0.61, p < 0.03), rigidity (Group A: r = 0.59, p < 0.004; Group B: r = 0.59, p < 0.04), but not with tremor.
Conclusion:
These findings indicate that regional metabolic covariance patterns are robust imaging markers of disease severity. FDG-PET may be useful clinically in assessing parkinsonian disability and disease progression.
More Related Videos
09:58Semi-quantitative Assessment Using [18F]FDG Tracer in Patients with Severe Brain Injury
Published on: November 9, 2018
06:53Management of Respiratory Motion Artefacts in 18F-fluorodeoxyglucose Positron Emission Tomography using an Amplitude-Based Optimal Respiratory Gating Algorithm
Published on: July 23, 2020
Related Concept Videos
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
![Quantification of Atherosclerotic Plaque Activity and Vascular Inflammation using [18-F] Fluorodeoxyglucose Positron Emission Tomography/Computed Tomography (FDG-PET/CT)](/_next/image?url=https%3A%2F%2Fcloudfront.jove.com%2FCDNSource%2Fteasers%2F3777.jpg&w=3840&q=50)