Patterns of osteolysis around total hip components inserted with and without cement
The Journal of Bone and Joint Surgery. American Volume
|March 1, 1995
Summary
Cemented acetabular components in total hip arthroplasty show a higher rate of osteolysis and loosening compared to uncemented components. Uncemented cups had less osteolysis, though it caused more bone loss.
Area of Science:
- Orthopedic Surgery
- Biomaterials Science
Background:
- Total hip arthroplasty (THA) is a common procedure for hip joint issues.
- Osteolysis, bone loss around implants, is a significant complication.
- The fixation method of acetabular components (cemented vs. uncemented) may influence osteolysis.
Purpose of the Study:
- To compare the incidence and characteristics of acetabular osteolysis between cemented and uncemented porous-coated acetabular components in THA.
- To evaluate the association between osteolysis patterns and component loosening.
Main Methods:
- Radiographic review of 137 patients (137 hips) undergoing THA with porous-coated femoral components.
- Categorization of acetabular components into cemented (Group A, n=63) and uncemented (Group B, n=74).
- Assessment for osteolysis and component loosening at a mean follow-up of 105 months.
Main Results:
- Acetabular osteolysis occurred in 37% of unrevised cemented cups, frequently linear and associated with 30% loosening.
- Acetabular osteolysis occurred in 18% of unrevised uncemented cups.
- Uncemented cups showed less osteolysis than cemented cups (p < 0.05), with localized, expansile osteolysis not linked to loosening but causing greater bone loss.
Conclusions:
- Cemented acetabular components in THA are associated with a higher rate of osteolysis and component loosening.
- Uncemented acetabular components demonstrate a lower incidence of osteolysis, although the pattern may lead to more significant bone loss without associated loosening.