Related Experiment Video
Updated: Jul 28, 2026

Clinical Application of Single-Surgeon, Three-Port, Laparoscopic Resection for Colorectal Cancer with Natural Orifice Specimen Extraction
Published on: March 24, 2023
Efficacy and safety of large-loop excision of the transformation zone
A Bigrigg1, D K Haffenden, A L Sheehan
1University Department of Obstetrics and Gynaecology, Southmead Hospital, Bristol, UK.
Abstract:
Large-loop excision of the transformation zone (LLETZ) has become a popular treatment for women with cervical intraepithelial neoplasia (CIN) before long-term effectiveness and safety have been fully evaluated. Women who took part in a 1990 study of the procedure have been followed-up by cervical cytology for longer than 2 years. The rate of recurrences and residual lesions was 5.0% in the first year and 0.6% in the second year. LLETZ was also effective when used as a repeat procedure, although the negative histology rate was much higher (4.7% for initial procedures and 20% for repeat procedures). 250 women from the original study group of 1000 answered a questionnaire on fertility and menstrual symptoms 3 years after LLETZ. We found no differences between these women and controls of the same age, living in the same geographical area, with a history of negative cervical smears. LLETZ is a safe and effective procedure with no effect on menstruation or fertility.
More Related Videos
04:08Evaluation of the Effectiveness of Longitudinal Incision for Endoscopic Submucosal Excavation of Gastric Subepithelial Lesions
Published on: April 28, 2026
04:09The Pocket-Creation Procedure of Endoscopic Submucosal Dissection for Large Rectal Laterally Spreading Tumors
Published on: February 13, 2026
Related Concept Videos
Reducing Line Loss
With a step-up transformer at the source, the voltage is increased, thereby reducing the current in the transmission lines since power loss in...
Radial System Protection
In a radial system with a fault downstream of the third breaker, ideally, only the third breaker will open, isolating the fault and interrupting the load connected beyond it. The second breaker has a longer delay setting,...
Reclosers and Fuses
A comprehensive protection scheme for radial distribution...
Directional Relays
Zones of Protection
Protective zones are defined by closed dashed lines, containing one or more components. A key characteristic of these zones is the strategic placement of...
Line Protection with Impedance Relays
Under normal conditions, low load currents keep the measured...