Assessing Cerebral Autoregulation via Oscillatory Lower Body Negative Pressure and Projection Pursuit Regression
Published on: December 10, 2014
Two ranges in blood pressure power spectrum with different 1/f characteristics
1I. Physiologisches Institut der Ruprecht-Karis, Universitat Heidelberg, Germany.
Abstract:
Most time series of biological systems contain a considerable amount of 1/f noise. This form of noise is characterized by fluctuations in which power steadily increases at lower frequencies. To determine the origin of 1/f noise, blood pressure (BP) was measured over 4 h in conscious foxhounds. The power spectrum of BP was obtained by fast Fourier analysis. After log-log transformation, the power spectrum (log power vs. log frequency) characteristically revealed a linear regression. Surprisingly, there were two 1/f ranges. The first 1/f region was located within a low-frequency range (< 10(-1.7) Hz; slope -0.9; r = -0.9). The second 1/f range was identified at 10(-1.4) to 10(-1) Hz (slope -1.2; r = -0.7). After baroreceptor denervation (n = 7), the steepness of both slopes increased significantly (P < 0.05 for lower 1/f range, P < 0.001 for higher 1/f range), and the difference in slopes was clearly greater (slope in lower range -1.2; r = 0.96 vs. -3.1, r = -0.92 in the higher range; P < 0.001). Neither alpha-receptor (n = 6) nor beta-receptor blockade (n = 4) considerably changed the slopes after denervation. However, autonomic blockade (n = 5) restored the slope in the low-frequency range (-0.9; r = -0.9). In conclusion, there are two independently modulated 1/f frequency ranges in BP time series. Baroreceptors especially attenuate 1/f noise in the higher frequency range.
Related Concept Videos
Pulse amplitude and quality
A weak or absent pulse may indicate reduced cardiac output or poor left ventricular contraction, which can be signs of cardiovascular dysfunction or...
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Blood Pressure
Measurement of Blood Pressure