Sub-kilohertz flash X-ray generator utilising a glass-enclosed cold-cathode triode

E Sato1, K Takahashi, M Sagae

  • 1Department of Physics, Iwate Medical University, Morioka, Japan.

Medical & Biological Engineering & Computing
|May 1, 1994
PubMed
Summary

This study details a new sub-kilohertz X-ray generator for low-dose rate flash X-rays. The device achieves high-intensity, microsecond pulses, enabling high-speed radiography applications.

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Clinical evaluation of human telomerase catalytic subunit in bladder washings from patients with bladder cancer.

Molecular urology·2001
Same author

Kudo total elbow arthroplasty in patients with rheumatoid arthritis: a long-term follow-up study.

The Journal of bone and joint surgery. American volume·2001
Same author

Histamine stimulates alveolar macrophages to release neutrophil and monocyte chemotactic activity.

The Journal of laboratory and clinical medicine·2001
Same author

Targeting superoxide dismutase to renal proximal tubule cells inhibits nephrotoxicity of cisplatin and increases the survival of cancer-bearing mice.

Cancer letters·2001
Same author

Constitutive nitric oxide synthase is associated with retinal vascular permeability in early diabetic rats.

Diabetologia·2001
Same author

Timing of the administration of tranexamic acid for maximum reduction in blood loss in arthroplasty of the knee.

The Journal of bone and joint surgery. British volume·2001

Area of Science:

  • Medical Imaging
  • Physics
  • Engineering

Background:

  • Flash X-ray generation is crucial for high-speed imaging.
  • Existing generators may have limitations in repetition rate or dose control.
  • Development of novel X-ray sources is needed for advanced applications.

Purpose of the Study:

  • To construct and study a novel sub-kilohertz X-ray generator.
  • To achieve low-dose rate flash X-ray production.
  • To evaluate the generator's performance for high-speed radiography.

Main Methods:

  • Designed and built a glass-enclosed cold-cathode triode X-ray tube.
  • Utilized a coaxial condenser charged up to 60 kV for energy storage.
  • Employed a negative high-voltage pulse on a trigger electrode for repetitive discharge.

Related Experiment Videos

  • Measured X-ray duration, intensity, and repetition rate.
  • Main Results:

    • The generator produced X-rays with durations of approximately 1 microsecond.
    • X-ray intensity reached about 0.47 microC kg-1 at 0.5 m per pulse (at 60 kV charged voltage).
    • Maximum repetition rate achieved was approximately 0.4 kHz.
    • High-speed radiography was successfully performed.

    Conclusions:

    • The constructed sub-kilohertz X-ray generator is capable of producing low-dose rate flash X-rays.
    • The device demonstrates potential for applications requiring high-speed imaging.
    • Further studies can explore optimization for specific radiography tasks.