Related Experiment Video
Updated: Aug 14, 2026

In Situ Monitoring of Diffusion of Guest Molecules in Porous Media Using Electron Paramagnetic Resonance Imaging
Published on: September 2, 2016
Insidious errors in dipole parameters due to shell model misspecification using multiple time-points
Z Zhang1, D L Jewett, G Goodwill
1Research Division, Abratech Corporation, Sausalito, California 94965.
Abstract:
Insidious errors in dipole modeling due to shell model misspecification in a spherical model were examined analyzing multiple time-points using the constraints of a commonly-used DSL (Dipole Source Localization) method. The computer simulation examined the differences in the fit dipole parameters for the same generator under two circumstances: 1) when computed as a single dipole active alone, and 2) when computed as a member of a simultaneously-active dipole pair. The computations were done using a simplification by which the dipole parameters computed from multiple time-points can be correctly assessed by computing dipole parameters at only two virtual time-points. Using multiple time-points in the DSL generally resulted in less error than if only a single time-point was used. However, how much improvement cna be achieved by using multiple time-points, as compared with a single time-point, is a function of many factors, such as the location and orientation of the dipoles, and the relative magnitudes and overlap of the waveforms (i.e., time-varying magnitudes) of the dipoles, as well as the model used in the fitting. Further, it was shown that it is incorrect to assume that a multiple-time-point DSL will compute a zero magnitude for generators during quiescent intervals. Additionally, it was shown that a "correction" to reduce error for one pair of waveforms will not be applicable to other waveforms. Also, even if location errors are eliminated, magnitude and orientation errors can still be shown to be present. Finally, iterative reduction of the least-square error between the observed and predicted surface maps leads to increasing errors in dipole parameters. We conclude that a DSL with model misspecification can contain insidious (undetectable) errors.
More Related Videos
08:54Vibrational Spectra of a N719-Chromophore/Titania Interface from Empirical-Potential Molecular-Dynamics Simulation, Solvated by a Room Temperature Ionic Liquid
Published on: January 25, 2020
08:04Excitonic Hamiltonians for Calculating Optical Absorption Spectra and Optoelectronic Properties of Molecular Aggregates and Solids
Published on: May 27, 2020
Related Concept Videos
Molecular Geometry and Dipole Moments
¹H NMR: Interpreting Distorted and Overlapping Signals
As Δν decreases and the signals move closer, the doublets appear increasingly distorted. The intensities of the inner lines increase at the cost of those of the outer lines as the signals are slanted or...
NMR Spectrometers: Resolution and Error Correction
Electric Dipoles and Dipole Moment
Theoretically, studying electric dipoles leads to understanding why the resultant electric forces around us are weak. Since electric forces are strong, remnant net charges are rare. Hence, the interaction between dipoles helps us understand electrical interactions in...
Induced Electric Dipoles
Since the absolute value of potential energy holds no physical meaning, its zero value can be chosen as per...
Calculations of Electric Potential II
Consider a...