Related Experiment Video
Updated: Sep 18, 2026

Determination of High-affinity Antibody-antigen Binding Kinetics Using Four Biosensor Platforms
Published on: April 17, 2017
Kinetics of antibody binding to surface-immobilized antigen. Analysis of data and an empiric model
1Department of Anatomy and Cell Biology, University of Göteborg, Sweden.
Abstract:
The kinetics of the reaction between monoclonal antibodies and surface-immobilized hapten (dinitrophenyl, DNP) was measured with in situ ellipsometry. A flow cuvette with a small volume (50 microliters) and a high flow rate (3 ml/min) was used in order to avoid mass-transport limitation of the reaction. An initial linear phase was recorded by off-null ellipsometry with a time resolution of 0.1 s. The linear phase was followed by an accelerated rate of antibody binding. The time dependence of the rapid reaction exhibited an exponential form. The apparent rate of antibody binding then decreased continuously with time and the surface concentration of bound antibodies was proportional to the logarithm of time. An empiric model is suggested that describes the time course and the concentration-dependence of the reaction.
Related Concept Videos
Antibody Structure
Antibodies, also known as immunoglobulins (Ig), are essential players of the adaptive immune system. These antigen-binding proteins are produced by B cells and make up 20 percent of the total blood plasma by weight. In mammals, antibodies fall into five different classes, which each elicits a different biological response upon antigen binding.
The Y-Shaped Structure of Antibodies Consists of Four Polypeptide Chains
Antibodies consist of four polypeptide chains: two identical heavy...
Affinity and Avidity
The Equilibrium Binding Constant and Binding Strength
Antibody Actions
Neutralization
Antibodies can bind to pathogens, preventing them from infecting host cells. This process...
Protein-Drug Binding: Determination Methods
Indirect methods involve isolating the bound drug from its free form in biological samples such as blood, serum, or plasma. These techniques aim to measure the percentage of drugs bound to proteins. Equilibrium dialysis is a commonly used method where the free drug concentration at equilibrium is measured by separating the bound...
Physiological Pharmacokinetic Models: Assumption with Protein Binding