Related Experiment Video
Updated: Jul 29, 2026

A Dual Tracer PET-MRI Protocol for the Quantitative Measure of Regional Brain Energy Substrates Uptake in the Rat
Published on: December 28, 2013
Regional distribution of 2-deoxy-2[18F]-fluoro-D-glucose for metabolic imaging using positron emission tomography
P Alagona1, D T Hart, E A Eikman
1St. Joseph's Positron Center, Medical Divison, Tampa, FL 33607-4227.
Abstract:
Radiopharmaceutical availability is one of the reasons dissemination and growth of clinical PET imaging remains problematic. A 'regional' cyclotron-radiopharmacy facility for the production of the positron emitting radionuclide 2-deoxy-2[18F]-fluoro-D-glucose (FDG), has been operational for over 2 years and supplies this radiopharmaceutical to five camera facilities, four distant and one on-site. The RDS 11 MeV cyclotron is capable of dual bombardment of targets yielding 60 GBq (1600 mCi) of F-18 in a 90 minute period. F-18 labelled FDG is produced by an automated synthesis module yielding 22.2 GBq (600 mCi) FDG. The PET radiopharmacy is required to perform extensive quality assurance activities including a number of tests to insure final product and safety. [18F]FDG is shipped in unit dose vials, 6 ml, two per shielded container, meeting Department of Transportation (DOT) specifications (43 x 43 cm cubes, styrofoam packing, 22 lb. lead shield). This adheres to regulations requiring no more than 200 millirem per hour (mR/Hr) exposure at the container surface, and 10 mR/hr at a distance of 1 meter. Total transport time, utilizing private air and ground couriers, to distant facilities is approximately 100-120 minutes. Based on patient scheduling and protocol used, allowing 45-60 minutes between dose administrations, and availability of 22.2 GBq (600 mCi), 20-22 unit doses can be supplied, divided and shipped in a number of ways. The regional-commercial distribution of PET radiopharmaceuticals, specifically [18F]FDG, is feasible. This provides availability of metabolic imaging at sites distant to radiopharmaceutical production.
More Related Videos
06:53Management of Respiratory Motion Artefacts in 18F-fluorodeoxyglucose Positron Emission Tomography using an Amplitude-Based Optimal Respiratory Gating Algorithm
Published on: July 23, 2020
09:03Radiotracer Administration for High Temporal Resolution Positron Emission Tomography of the Human Brain: Application to FDG-fPET
Published on: October 22, 2019
Related Concept Videos
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET