Analysis of urinary benzodiazepines using solid-phase extraction and gas chromatography-mass spectrometry
Abstract:
A solid-phase extraction and GC-MS confirmation method was developed for certain urinary diazolo- and triazolobenzodiazepines, including the metabolites of lorazepam, clonazepam, alprazolam, and triazolam. The latter two do not form benzophenones, and the others are not readily confirmed by conventional thin-layer chromatography or GC-MS techniques. Samples were hydrolyzed with glucuronidase at 37 degrees C, adjusted to pH 4.5, extracted with Bond Elut Certify columns, dried, and derivatized using BSTFA with 1% TMCS. Sample preparation time averaged 4 hours. A GC-MS selected-ion-monitoring acquisition method targeting retention time, molecular ion abundances, and qualifier ion ratios was used to determine positive results. The recovery of 7-NH2-clonazepam was 95%, and recoveries of alpha-hydroxyalprazolam, alpha-hydroxytriazolam, and lorazepam were greater than 66%. Linearity was demonstrated from 0.1 to 1.0 microgram/mL for each drug. Within-run CVs were less than 11%, and between-run CVs were less than 16%. Using this technique, we have been able to confirm suspected cases of abuse that had not been confirmed by previous techniques.
More Related Videos
10:17High-throughput and Comprehensive Drug Surveillance Using Multisegment Injection-Capillary Electrophoresis-Mass Spectrometry
Published on: April 23, 2019
05:31Gas Chromatography-Mass Spectrometry Paired with Total Vaporization Solid-Phase Microextraction as a Forensic Tool
Published on: May 25, 2021
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a column.
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
High-Performance Liquid Chromatography: Types of Detectors
Ion-Exchange Chromatography