Electrocardiographic inverse solution for ectopic origin of excitation in two-dimensional propagation model
Related Experiment Video
Updated: Nov 6, 2026

Patient-specific Modeling of the Heart: Estimation of Ventricular Fiber Orientations
Published on: January 8, 2013
1Department of Biomedical Engineering and Pediatrics, Duke University, Durham, NC 27708.
Abstract:
Inverse calculations were examined that sought the origin of a cardiac ectopic excitation sequence. Cardiac anatomy and its geometric relationships to sites on the body surface were adapted from human cross-sectional images to form a two-dimensional model, which included ventricular muscle and a primitive conduction system. The surrounding volume conductor was modelled in a simplified way as unbounded, homogeneous and isotropic. In a series of tests, one ectopic origin was designated the 'true' origin. The ECG for this true origin was compared to ECGs for 197 ectopic 'trial' origins, and differences between the wave forms for true versus trial origins were determined. Core issues were the magnitudes of changes in ECG wave forms as a function of the site of origin, whether these changes were sufficient to imply uniqueness, and what spatial resolution might be expected, in the presence of realistic noise levels. For a noise level of 10 microV RMS, the origin of excitation was localised to a single region of the muscle using one wave form from the body surface, with a resolution of 10 mm. The resolution was not improved significantly with a second electrode on the body surface, but was substantially improved with an endocardial electrode.
Related Concept Videos
Electrophysiology of Normal Cardiac Rhythm
Bode Plots Construction
Electrocardiogram
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and the T...
Correlation between ECG and Cardiac Cycle
A cardiac action potential originates in the SA node and spreads throughout the atria and the AV node in approximately 0.03 seconds. This results in the P wave in an ECG and triggers atrial contraction. The action potential is then briefly slowed at the AV node, allowing the atria to contract and fill the ventricles with blood before...
Cardiac Action Potential
The cardiac action potential process involves a series of phases characterized by the movement of ions across the cardiac cell membranes, leading to the depolarization and repolarization of the cardiac myocytes.
Ionic Basis of Cardiac Action Potentials
Electrocardiogram Fundamentals
An electrocardiogram (ECG) is a diagnostic tool for identifying cardiac conditions such as arrhythmias, conduction abnormalities, and myocardial ischemia.
Definition
An electrocardiogram (ECG) visualizes the heart's electrical activity by tracing the electrical movement associated with each heartbeat on a graph or monitor. As the heart beats, an electrical wave passes through it, correlating with the cardiac cycle events.
Parts of an ECG
An ECG utilizes electrodes on the skin to...

