[Clinical and radiological results with the spherical Mecring as acetabulum prosthesis in hip joint diseases]
Abstract:
The recent experiences which the university hospital in Heidelberg has made with the spherical Mecring must be valued positively. Clinical, radiological and subjective dates from 147 patients were worked up retrospectively. Indeed, the positive results must be considered as relative because of the short respectively medium-term period of control. Nevertheless, the repeated improvement in the second group after a period of postexamination on a average of 3.05 years lets hope for positive long-term results. In the period between 1985 and 1990 three sockets had to be changed. The reasons that the sockets loosened were not specific for the screwing but depending on the individual patients or on the implantations and technical circumstances. The negative results achieved by Engh et al. 1990 could not be recognized (8). He measured a radiological instability of 18% and a technical instability of 28%. What Engh did was measuring simple review photographs and extracting valuable material from them while using geometrical methods. This method shows various measuring mistakes. Therefore Engh's conclusion that the screwing should not be used for implantation because of its displacement in the bones is doubtful. The doubts seem to be supported by the results of our comparison of two series of X-ray photographs with defined different pelvis positions of the same patient. The screwing seemed to be significantly displaced in cranio-medial direction. This was proved by experimental photographs with a pelvis raised to 6 cm in contralateral direction. But the results were a matter of radiological illusion. Radiological migration of the screwing is only provable by complicated X-ray analyses steered with the computer. These big X-ray series are not accessible at the time.
Insights
The spherical Mecring shows positive clinical outcomes in hip arthroplasty patients, with medium-term results suggesting potential for good long-term success. Loosening causes were patient- or surgery-related, not specific to the implant design.
Area of Science:
- Orthopedic Surgery
- Biomedical Engineering
- Radiology
Background:
- The spherical Mecring is a prosthetic implant used in hip arthroplasty.
- Assessing implant stability and patient outcomes is crucial for surgical success.
Purpose of the Study:
- To evaluate the clinical, radiological, and subjective outcomes of the spherical Mecring in hip arthroplasty.
- To compare findings with previous studies and address potential measurement inaccuracies.
Main Methods:
- Retrospective analysis of clinical, radiological, and subjective data from 147 patients.
- Comparison of X-ray images with varying pelvic positions to assess implant migration.
- Critique of geometrical methods used in prior radiological assessments.
Main Results:
- Positive medium-term outcomes were observed, with a low revision rate (3 sockets changed between 1985-1990).
- Loosening causes were attributed to patient-specific or technical factors, not the implant itself.
- Radiological instability findings contradicted previous studies, suggesting methodological limitations in prior assessments.
Conclusions:
- The spherical Mecring demonstrates positive initial and medium-term results in hip arthroplasty.
- Previous claims of high instability may be due to flawed radiological assessment methods.
- Further computer-assisted radiological analysis is needed for definitive long-term migration assessment.