The effectiveness of immobilization during prostate irradiation
G C Bentel1, L B Marks, G W Sherouse
1Department of Radiation Oncology, Duke University, Durham, NC.
International Journal of Radiation Oncology, Biology, Physics
|January 1, 1995
Summary
A custom hemibody foam cradle improved patient setup reproducibility in prostate cancer radiation therapy. This immobilization device is now standard practice, especially for dose escalation to protect surrounding organs.
Area of Science:
- Radiation Oncology
- Medical Physics
- Cancer Treatment
Background:
- Accurate patient positioning is crucial for effective external beam radiation therapy (EBRT).
- Variability in daily setup can lead to under- or over-dosing of the target volume and surrounding organs at risk.
- Immobilization devices aim to reduce setup inconsistencies during fractionated radiotherapy.
Purpose of the Study:
- To assess the impact of a custom-made hemibody foam cradle on patient setup reproducibility.
- To evaluate its effect on isocenter shifts during prostate cancer radiation treatment.
Main Methods:
- A cohort of 74 prostate cancer patients undergoing EBRT were analyzed.
- Forty-four patients used a custom hemibody foam cradle for immobilization.
- Weekly port films were reviewed retrospectively to quantify isocenter shifts, comparing immobilized to non-immobilized groups.
Main Results:
- Patients using the foam cradle showed a trend towards improved overall setup reproducibility (17.4% vs. 23.1% isocenter shifts).
- A statistically significant reduction in anterior-posterior isocenter shifts was observed in the immobilized group (5.1% vs. 12.6%, p < 0.05).
- No significant improvement was noted in cephalad-caudal or right-left directions.
Conclusions:
- The custom hemibody foam cradle enhances patient setup reproducibility during prostate cancer radiotherapy.
- This immobilization technique is now routinely used and recommended for pelvic radiotherapy.
- It is particularly beneficial for dose escalation strategies to minimize radiation to the bladder and rectum.